超声引导下经股静脉隧道式中心静脉置管后确认性X线摄片价值有限

Confirmatory radiographs have limited utility following ultrasound-guided tunneled femoral central venous catheter placements by interventional radiology.
PubMed 文献 · Pediatr Radiol · 2021-02-05

本研究回顾性分析2016年1月1日至2020年4月20日单中心484例儿科患者床旁超声引导下经股静脉隧道式中心静脉置管,技术成功率99.4%,不良事件发生率1.0%。171例(35.3%)术后12小时内摄片,其导管尖端位置与术中超声100%一致,作者认为常规术后X线摄片无必要,仅在操作者不确定或临床担忧时进行。

要点

  • 术中超声与术后确认性X线摄片对导管尖端位置判断100%一致。
  • 术后常规X线摄片对超声引导下股静脉中心静脉置管价值有限。
  • 仅在操作者不确定或临床担忧时,可考虑行X线摄片确认。

诊断标准与关键数值

  • 技术成功率为99.4%(481/484),技术失败3例(0.6%)因既往未诊断的髂股静脉闭塞性疾病。
  • 不良事件发生率为1.0%(5/484)。
  • 171例(35.3%)患者在置管后12小时内行X线摄片,其中120例(70.2%)摄片指征为近期置管。
  • 全部171例(100%)术后X线摄片显示导管尖端位置与术中超声一致。
  • 1例(0.2%)患者术中超声引导下置管时导丝未显影且临床怀疑位置异常,术后X线摄片联合多平面静脉造影证实导管误入椎旁静脉丛。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

BACKGROUND: Ultrasonography may reliably visualize both appropriately positioned and malpositioned femoral-approach catheter tips. Radiography may be used to confirm catheter tip position after placement, but its utility following intraprocedural ultrasound (US) catheter tip verification is unclear.

OBJECTIVES: To report the utility of confirmatory radiographs after US-guided tunneled femoral central venous catheter (CVC) placements by interventional radiology in pediatric patients.

MATERIALS AND METHODS: A total of 484 pediatric patients underwent bedside US-guided tunneled femoral CVC placements in an intensive care setting at a single tertiary children's hospital between Jan. 1, 2016, and April 20, 2020. Technical success, adverse events, post-procedure radiographic practices and inter-modality catheter tip concordance were recorded. All radiographs were performed within 12 h of catheter placement.

RESULTS: The mean patient age was 175±508 days (range: 1 day to 19 years), including 257 (53.1%) males and 227 (46.9%) females. Of the 484 attempted placements, 472 (97.5%) were primary placements. Four hundred eighty-one (99.4%) placements were technically successful. There were three (0.6%) technical failures due to previously undiagnosed iliofemoral venous occlusive disease. Five (1.0%) adverse events occurred. Radiographs were obtained within 12 h of CVC placement in 171 (35.3%) patients, in 120 (70.2%) of whom the indication was recent catheter placement. All 171 (100%) post-placement radiographs showed catheter tip location concordance with the intra-procedural US. In one (0.2%) patient, in whom there was nonvisualization of a guidewire and clinical concern for malposition during US-guided placement, post-procedure radiographs, coupled with multiplanar venography, demonstrated inadvertent paravertebral venous plexus catheter placement.

CONCLUSION: The concordance between intra-procedural US and confirmatory post-procedure radiographs of CVC placements by interventional radiology obviates the need for routine radiographs. Radiographs may be obtained in instances of proceduralist uncertainty or clinical concern.

来源:Pediatr Radiol,查看原文。版权归原作者所有。

引用

  1. Lewis SB, Chick JFB, Koo KSH, et al. Confirmatory radiographs have limited utility following ultrasound-guided tunneled femoral central venous catheter placements by interventional radiology. Pediatr Radiol. 2021. PMID: 33544192. doi:10.1007/s00247-020-04957-x

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。