该研究纳入10例单侧痉挛型脑瘫儿童,由两名不同经验水平的研究者在间隔1周的两次 sessions 中,于中立位和最大背屈角度对双下肢胫骨前肌和腓肠肌内侧头行剪切波弹性成像与超声测量。结果显示剪切模量测量的信度不足(中立位 CV>10%,最大背屈位 CV>20%),而肌肉厚度测量在双下肢双肌肉中均显示良好信度(CV>10%,ICC>0.74)。作者结论认为剪切波弹性成像测量须采用严格标准化方案,而肌肉厚度应被视为监测肌肉形态变化的重要参数。

要点

  • 剪切模量测量信度不足,中立位 CV>10%、最大背屈位 CV>20%,阅片解读需谨慎。
  • 肌肉厚度测量信度良好(CV>10%,ICC>0.74),可作为监测肌肉形态变化的参数。
  • 剪切波弹性成像须采用严格标准化方案,不同经验水平研究者间测量需规范。

诊断标准与关键数值

  • 剪切模量测量信度不足:中立位 CV>10%,最大背屈位 CV>20%。
  • 肌肉厚度测量信度良好:双下肢双肌肉 CV>10%,ICC>0.74。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

In clinical practice, few data exist on the feasibility of performing reliable shear wave elastography (SWE) and ultrasonography (US) measurements in spastic muscles of children with cerebral palsy (CP). Ten children with unilateral CP took part in SWE and US assessment of the tibialis anterior and medialis gastrocnemius muscles during two sessions separated by a 1-wk interval. Intra- and inter-investigator reliability of shear modulus (µ) and muscle thickness (MT) measurements, at neutral and maximal dorsiflexion angles on both legs, was assessed by two investigators with different levels of experience. Reliability was assessed with the coefficient of variation (CV), standard error of measurement and intra-class correlation coefficient (ICC). Reliability of the µ measurement was insufficient, regardless of angle position (CV >10% and >20% for neutral and maximal dorsiflexion angles, respectively). The intra- and inter-investigator reliability of MT measurements was good (CV >10%, ICC >0.74) for both muscles in both legs. SWE measurements must be performed using a rigorous standardized protocol while MT should be considered an important parameter to monitor change in muscle morphology.

来源:Ultrasound Med Biol,查看原文。版权归原作者所有。