磁化准备双快速梯度回波MRI用于髋关节软骨B1不敏感三维T1成像:实验与临床验证

Magnetization-prepared 2 Rapid Gradient-Echo MRI for B1 Insensitive 3D T1 Mapping of Hip Cartilage: An Experimental and Clinical Validation.
PubMed 文献 · Radiology · 2021-02-23

研究在体模、健康志愿者和髋痛受试者中比较三维MP2RAGE与三维双翻转角技术行3.0T髋关节软骨T1成像,以二维反转恢复T1为参考标准。体模中MP2RAGE的T1偏差低于双翻转角技术(平均3毫秒±11 vs 253毫秒±85,P<.001),且MP2RAGE偏差与B1偏差增加不相关。髋痛受试者中MP2RAGE相对二维反转恢复的平均T1偏差为-23毫秒±31(P<.001)。

要点

  • 体模中MP2RAGE的T1偏差明显低于双翻转角技术,且不受B1偏差增大影响。
  • 健康志愿者中仅双翻转角技术观察到区域软骨T1差异(109毫秒±163,P=.008)。
  • 髋痛受试者中MP2RAGE相对二维反转恢复的平均T1偏差为-23毫秒±31(P<.001)。

诊断标准与关键数值

  • 体模中相对二维反转恢复的T1偏差:三维MP2RAGE平均3毫秒±11,三维双翻转角技术平均253毫秒±85(P<.001)。
  • 健康志愿者中仅三维双翻转角技术观察到区域软骨T1差异(109毫秒±163,P=.008)。
  • 髋痛受试者中三维MP2RAGE相对二维反转恢复的平均T1偏差为-23毫秒±31(P<.001)。

临床应用与阅片要点

  • 作者结论认为三维MP2RAGE较三维双翻转角技术能提供更准确的髋关节软骨T1成像,且受B1不均匀性影响更小。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

Background Often used for T1 mapping of hip cartilage, three-dimensional (3D) dual-flip-angle (DFA) techniques are highly sensitive to flip angle variations related to B1 inhomogeneities. The authors hypothesized that 3D magnetization-prepared 2 rapid gradient-echo (MP2RAGE) MRI would help provide more accurate T1 mapping of hip cartilage at 3.0 T than would 3D DFA techniques. Purpose To compare 3D MP2RAGE MRI with 3D DFA techniques using two-dimensional (2D) inversion recovery T1 mapping as a standard of reference for hip cartilage T1 mapping in phantoms, healthy volunteers, and participants with hip pain. Materials and Methods T1 mapping at 3.0 T was performed in phantoms and in healthy volunteers using 3D MP2RAGE MRI and 3D DFA techniques with B1 field mapping for flip angle correction. Participants with hip pain prospectively (July 2019-January 2020) underwent indirect MR arthrography (with intravenous administration of 0.2 mmol/kg of gadoterate meglumine), including 3D MP2RAGE MRI. A 2D inversion recovery-based sequence served as a T1 reference in phantoms and in participants with hip pain. In healthy volunteers, cartilage T1 was compared between 3D MP2RAGE MRI and 3D DFA techniques. Paired t tests and Bland-Altman analysis were performed. Results Eleven phantoms, 10 healthy volunteers (median age, 27 years; range, 26-30 years; five men), and 20 participants with hip pain (mean age, 34 years ± 10 [standard deviation]; 17 women) were evaluated. In phantoms, T1 bias from 2D inversion recovery was lower for 3D MP2RAGE MRI than for 3D DFA techniques (mean, 3 msec ± 11 vs 253 msec ± 85; P < .001), and, unlike 3D DFA techniques, the deviation found with MP2RAGE MRI did not correlate with increasing B1 deviation. In healthy volunteers, regional cartilage T1 difference (109 msec ± 163; P = .008) was observed only for the 3D DFA technique. In participants with hip pain, the mean T1 bias of 3D MP2RAGE MRI from 2D inversion recovery was -23 msec ± 31 (P < .001). Conclusion Compared with three-dimensional (3D) dual-flip-angle techniques, 3D magnetization-prepared 2 rapid gradient-echo MRI enabled more accurate T1 mapping of hip cartilage, was less affected by B1 inhomogeneities, and showed high accuracy against a T1 reference in participants with hip pain. © RSNA, 2021.

来源:Radiology,查看原文。版权归原作者所有。

引用

  1. Schmaranzer F, Afacan O, Lerch TD, et al. Magnetization-prepared 2 Rapid Gradient-Echo MRI for B1 Insensitive 3D T1 Mapping of Hip Cartilage: An Experimental and Clinical Validation. Radiology. 2021. PMID: 33620288. doi:10.1148/radiol.2021200085

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。