全髋关节置换术后股骨柄前倾角测量:后髁 tangent 与经上髁轴比较
该研究纳入91例连续的全髋关节置换术后CT扫描,采用手术规划软件分别以后髁 tangent 和经上髁轴为远端参考测量股骨柄前倾角。结果显示两种方法组内相关系数良好(0.954),但平均差异为5.27±2.41°,且该差异不受髁部形态影响。作者认为经上髁轴可重复性更好,应优先用于测量股骨柄前倾角。
要点
- 经上髁轴测量股骨柄前倾角的观察者间和观察者内可靠性优于后髁 tangent。
- 两种方法测量的前倾角平均差异为5.27±2.41°,可能对联合前倾角产生10-20%的影响。
- 后髁形态(前后径差值及比值)不影响两种方法的前倾角差异(p=0.797和p=0.901)。
局限性
- 原文未报告局限性
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE: Stem anteversion in total hip arthroplasty (THA) has been measured using two different distal references, the posterior condyle (PC) or the transepicondylar axis (TEA). The reliability, the difference in value between these two techniques, and the possible confounding factors are scarcely known. Aims of this work were to assess (1) the intraclass correlation and the difference between the two measurement techniques and (2) the possible influence of condylar dysmorphisms on the anteversion value discrepancy.
MATERIALS AND METHODS: A consecutive series of post-THA CT scans were selected, excluding hip dysplasia, end-stage knee osteoarthritis, and replaced knees. Using a surgical planning software, stem anteversion was measured using the PC or the TEA reference. The intraclass reliability was assessed. The anteroposterior femoral condyle diameters were measured: the difference and the ratio were measured and correlated with the stem anteversion values.
RESULTS: 91 CT scans were included. Inter/intra-observer TEA measurements were more reliable than PC. The intraclass correlation between PC and TEA anteversion measurements was good, 0.954 (CI 95% 0.922-0965). The mean difference between PC and TEA anteversion was 5.27 ± 2.41°. The difference and the ratio between the two anteroposterior condyle diameters did not influence the anteversion difference (respectively, p 0.797 and p 0.901).
CONCLUSIONS: TEA and PC demonstrated to achieve a good correlation, not dependent from the condyle morphology. However, the difference between the two measurements (5°) can severely influence the combined anteversion (10-20%): due to clinical applicability and better inter/intra-observer agreement, TEA should be preferred for measuring stem anteversion.
引用
- Castagnini F, Giardina F, Tassinari E, et al. Measuring stem anteversion after total hip arthroplasty: posterior condylar tangent versus transepicondylar axis. Skeletal Radiol. 2021. PMID: 33532940. doi:10.1007/s00256-021-03725-8