文献速递骨肌技术与安全DR

机器学习优化腰椎X线悬挂协议

Hanging protocol optimization of lumbar spine radiographs with machine learning.
PubMed 文献 · Skeletal Radiol · 2021-02-15

本研究纳入1727例患者的6988张腰椎X线片,由委员会认证放射科医师手工标注视图、硬件、动态位置及矫正旋转。机器学习分类模型AUC为0.985至1.000;旋转校正模型在不同测试集上平均绝对差异分别为0.610、4.801和3.083。结论认为机器学习可成功优化腰椎X线悬挂协议。

要点

  • 分类模型对视图、硬件和动态位置的AUC达0.985至1.000
  • 旋转校正模型在仅0旋转测试集上平均绝对差异为0.610
  • 在非0旋转测试集上平均绝对差异为4.801,全病例为3.083

诊断标准与关键数值

  • 分类模型(视图、硬件、动态位置)的AUC范围为0.985至1.000。
  • 仅0旋转测试集:20度与60度模型取绝对最小值的集成表现最佳,平均绝对差异为0.610。
  • 非0旋转测试集:40度与160度模型取绝对最大值的集成表现最佳,平均绝对差异为4.801。
  • 全病例测试集:20度与40度模型取最小值的集成表现最佳,平均绝对差异为3.083。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: The purpose of this study was to determine whether machine learning algorithms can be utilized to optimize the hanging protocol of lumbar spine radiographs. Specifically, we explored whether machine learning models can accurately label lumbar spine views/positions, detect hardware, and rotate the lateral views to straighten the image.

METHODS: We identified 1727 patients with 6988 lumbar spine radiographs. The view (anterior-posterior, right oblique, left oblique, left lateral, right lateral, left lumbosacral or right lumbosacral), hardware (present or not present), dynamic position (neutral, flexion, or extension), and correctional rotation of each radiograph were manually documented by a board-certified radiologist. Various output metrics were calculated, including area under the curve (AUC) for the categorical output models (view, hardware, and dynamic position). For non-binary categories, an all-versus-other technique was utilized designating one category as true and all others as false, allowing for a binary evaluation (e.g., AP vs. non-AP or extension vs. non-extension). For correctional rotation, the degree of rotation required to straighten the lateral spine radiograph was documented. The mean absolute difference was calculated between the ground truth and model-predicted value reported in degrees of rotation. Ensembles of the rotation models were created. We evaluated the rotation models on 3 test dataset splits: only 0 rotation, only non-0 rotation, and all cases.

RESULTS: The AUC values for the categorical models ranged from 0.985 to 1.000. For the only 0 rotation data, the ensemble combining the absolute minimum value between the 20- and 60-degree models performed best (mean absolute difference of 0.610). For the non-0 rotation data, the ensemble merging the absolute maximum value between the 40- and 160-degree models performed best (mean absolute difference of 4.801). For the all cases split, the ensemble combining the minimum value of the 20- and 40-degree models performed best (mean absolute difference of 3.083).

CONCLUSION: Machine learning techniques can be successfully implemented to optimize lumbar spine x-ray hanging protocols by accounting for views, hardware, dynamic position, and rotation correction.

来源:Skeletal Radiol,查看原文。版权归原作者所有。

引用

  1. Kitamura G. Hanging protocol optimization of lumbar spine radiographs with machine learning. Skeletal Radiol. 2021. PMID: 33590305. doi:10.1007/s00256-021-03733-8

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。