文献速递骨肌神经MR

脊柱骨肿瘤的影像组学机器学习分类器:多软件、多扫描仪研究

Radiomic Machine Learning Classifiers in Spine Bone Tumors: A Multi-Software, Multi-Scanner Study.
PubMed 文献 · Eur J Radiol · 2021-02-10

该回顾性研究纳入146例因椎体病变行MRI的患者,分为训练集100例、内部测试集46例及多扫描仪外部测试集35例,评估3D Slicer hCAD与PyRadiomics提取的影像组学特征联合机器学习分类器对脊柱病变的鉴别诊断性能。二分类(良恶性)中hCAD数据内部测试集准确率94%、外部测试集86%;三分类中PyRadiomics数据内部与外部测试集准确率分别为80%和69%。作者认为MRI影像组学联合机器学习可能有助于脊柱病变评估,更稳健的预处理可在扫描仪和协议异质性下获得更好一致性。

要点

  • 二分类良恶性时hCAD数据内部测试集准确率94%、外部测试集86%,优于三分类。
  • 三分类时PyRadiomics数据内部测试集准确率80%、外部测试集69%。
  • 更稳健的预处理可能使结果在扫描仪和协议异质性下更一致。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: Spinal lesion differential diagnosis remains challenging even in MRI. Radiomics and machine learning (ML) have proven useful even in absence of a standardized data mining pipeline. We aimed to assess ML diagnostic performance in spinal lesion differential diagnosis, employing radiomic data extracted by different software.

METHODS: Patients undergoing MRI for a vertebral lesion were retrospectively analyzed (n = 146, 67 males, 79 females; mean age 63 ± 16 years, range 8-89 years) and constituted the train (n = 100) and internal test cohorts (n = 46). Part of the latter had additional prior exams which constituted a multi-scanner, external test cohort (n = 35). Lesions were labeled as benign or malignant (2-label classification), and benign, primary malignant or metastases (3-label classification) for classification analyses. Features extracted via 3D Slicer heterogeneityCAD module (hCAD) and PyRadiomics were independently used to compare different combinations of feature selection methods and ML classifiers (n = 19).

RESULTS: In total, 90 and 1548 features were extracted by hCAD and PyRadiomics, respectively. The best feature selection method-ML algorithm combination was selected by 10 iterations of 10-fold cross-validation in the training data. For the 2-label classification ML obtained 94% accuracy in the internal test cohort, using hCAD data, and 86% in the external one. For the 3-label classification, PyRadiomics data allowed for 80% and 69% accuracy in the internal and external test sets, respectively.

CONCLUSIONS: MRI radiomics combined with ML may be useful in spinal lesion assessment. More robust pre-processing led to better consistency despite scanner and protocol heterogeneity.

来源:Eur J Radiol,查看原文。版权归原作者所有。

引用

  1. Chianca V, Cuocolo R, Gitto S, et al. Radiomic Machine Learning Classifiers in Spine Bone Tumors: A Multi-Software, Multi-Scanner Study. Eur J Radiol. 2021. PMID: 33610852. doi:10.1016/j.ejrad.2021.109586

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。