文献速递甲状腺与浅表US

多参数超声评估甲状腺:弹性成像作为Bethesda III和IV类不确定结节恶性风险预测的关键工具——组织病理学对照

Multiparametric Ultrasound Evaluation of the Thyroid: Elastography as a Key Tool in the Risk Prediction of Undetermined Nodules (Bethesda III and IV)-Histopathological Correlation.
PubMed 文献 · Ultrasound Med Biol · 2021-02-12

这项前瞻性诊断准确性研究纳入62个细针穿刺活检细胞学不确定(Bethesda III/IV)的甲状腺结节,采用B模式、彩色多普勒及二维剪切波弹性成像评估,并与切除组织病理对照,其中良性35/62(56.4%)、癌27/62(43.6%)。多因素分析显示结节与甲状腺前肌群的平均变形比(MDR,单位kPa)是 indeterminate 结节风险分析的最佳参数,MDR>1.53的结节恶性概率更高(AUC-ROC=0.98)。作者结论认为二维剪切波弹性成像能够从细胞学不确定结节中筛选出恶性结节,从而避免这些细胞学分组的不必要手术。

要点

  • MDR(结节与甲状腺前肌群平均变形比,kPa)为Bethesda III/IV结节恶性风险的最佳参数(AUC-ROC=0.98)。
  • MDR>1.53的结节恶性概率更高。
  • 单因素分析中低回声、纵横比大于1及所有多普勒和弹性成像参数有统计学意义。

关键影像表现/征象

  • B模式超声评估结节回声、尺寸、轮廓、晕环及微钙化。
  • 多普勒超声评估血管化(仅周边或周边为主或中央)及三条结节动脉的平均阻力指数。
  • 弹性成像评估结节弹性成像模式、平均结节变形指数、结节与邻近甲状腺实质的变形比以及结节与甲状腺前肌群的平均变形比(MDR)。

诊断标准与关键数值

  • 单因素分析中有统计学意义的参数为低回声、结节直径大于宽度以及多普勒和弹性成像分析的所有参数。
  • 多因素分析显示MDR(单位kPa)是 indeterminate 结节风险分析的最佳参数。
  • MDR>1.53的结节恶性概率更高,AUC-ROC=0.98。

临床应用与阅片要点

  • 对Bethesda III/IV细胞学不确定的甲状腺结节,可参考MDR>1.53作为恶性风险预测指标(作者结论)。
  • 二维剪切波弹性成像可能有助于从细胞学不确定结节中筛选恶性结节,避免不必要手术(作者结论)。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

The purpose of this study was to select thyroid nodules most at risk for malignancy among those cytologically undetermined by fine-needle aspiration biopsy (FNAB), using B-mode, color duplex Doppler and 2-D shear wave shear wave elastography (2-D-SWE). This was a prospective diagnostic accuracy study with 62 Bethesda III/IV nodules according to FNAB (atypia/follicular lesion of undetermined significance or follicular neoplasia/Hürthle cell neoplasm). Ultrasonography (US) data were compared with resection histologic results, revealing 35 of 62 benign nodules (56.4%) and 27 of 62 carcinomas (43.6%). Conventional US was uses to evaluate nodule echogenicity, dimensions, contours, presence of halo and microcalcifications. Doppler US was used to assess the vascularization (exclusively or predominantly peripheral or central) and mean resistance index of three nodule arteries. Elastography was used to evaluate the nodule elastographic pattern; mean nodule deformation index; deformation ratio between nodule and adjacent thyroid parenchyma; and mean deformation ratio between nodule and pre-thyroid musculature (MDR). Statistical analysis included χ2, Fisher's exact, Student's t, Mann-Whitney tests and multivariable analysis by multiple logistic regression. Areas under the receiver operating characteristic curves (AUC-ROCs) were used for accuracy analysis. Fifty-eight participants (54.7 ± 14.0 y, 51 women) were studied. The parameters that were statistically significant to the univariate analysis were hypo-echogenicity, nodule diameter greater than width and all parameters analyzed from Doppler and elastography. Multivariate analysis revealed that the MDR (in kPa) was the best parameter for risk analysis of indeterminate nodules. Nodules with MDRs >1.53 exhibited a greater chance of malignancy (AUC-ROC = 0.98). We conclude that 2-D-SWE is able to select malignant nodules among those cytologically indeterminate, thus avoiding unnecessary surgery in these cytologic groups.

来源:Ultrasound Med Biol,查看原文。版权归原作者所有。

引用

  1. Moraes PHM, Takahashi MS, Vanderlei FAB, et al. Multiparametric Ultrasound Evaluation of the Thyroid: Elastography as a Key Tool in the Risk Prediction of Undetermined Nodules (Bethesda III and IV)-Histopathological Correlation. Ultrasound Med Biol. 2021. PMID: 33583638. doi:10.1016/j.ultrasmedbio.2021.01.019

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。