文献速递甲状腺与浅表US

ACR TI-RADS分类与剪切波弹性成像鉴别甲状腺结节的诊断价值

The Diagnostic Value of the American College of Radiology Thyroid Imaging Reporting and Data System Classification and Shear-Wave Elastography for the Differentiation of Thyroid Nodules.
PubMed 文献 · Ultrasound Med Biol · 2021-02-12

回顾性纳入2015年1月至2020年8月接受甲状腺切除术的141例患者(年龄18–84岁),以病理结果为参考标准,评估ACR TI-RADS分类与剪切波弹性成像(SWE)对甲状腺良恶性结节的诊断准确性。ROC曲线分析得出ACR TI-RADS分类的截断值为4类(AUC=0.684,p=0.020),剪切波速度(Vs)的截断值为5 m/s(AUC=0.715,p=0.005)。SWE诊断准确性高于ACR TI-RADS分类系统,可改善所有大小结节的鉴别,且结节直径增大时诊断效能下降。

要点

  • ACR TI-RADS分类截断值为4类,AUC=0.684(p=0.020)。
  • 剪切波速度截断值为5 m/s,AUC=0.715(p=0.005),诊断准确性高于ACR TI-RADS。
  • SWE可改善所有大小甲状腺结节的鉴别,但结节直径增大时诊断效能下降。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

This study aimed to determine the diagnostic accuracy of the American College of Radiology Thyroid Imaging Reporting and Data System (ACR TI-RADS) classification and shear-wave elastography (SWE) for the diagnosis of benign and malignant thyroid nodules. This retrospective study enrolled 141 patients (18-84 y of age) undergoing thyroidectomy between January 2015 and August 2020. All statistical analysis was based on pathologic results of patients. The cut-off value was found as category 4 for ACR TI-RADS classification and 5 m/s for shear-wave velocity (Vs) by the receiver operator characteristic curve analysis (area under the curve [AUC] = 0.684, p = 0.020 and AUC = 0.715, p = 0.005, respectively). SWE has higher diagnostic accuracy than the ACR TI-RADS classification system and can improve thyroid nodule discrimination in all sizes of the nodules. Also, the diagnostic performance decreases when the nodule diameter increases.

来源:Ultrasound Med Biol,查看原文。版权归原作者所有。

引用

  1. Bora Makal G, Aslan A. The Diagnostic Value of the American College of Radiology Thyroid Imaging Reporting and Data System Classification and Shear-Wave Elastography for the Differentiation of Thyroid Nodules. Ultrasound Med Biol. 2021. PMID: 33589354. doi:10.1016/j.ultrasmedbio.2021.01.023

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。