芬兰东部乳腺癌女性乳腺X线密度分布及BI-RADS第4版与第5版密度报告比较

The mammographic breast density distribution of Finnish women with breast cancer and comparison of breast density reporting using the 4th and 5th editions of the Breast Imaging-Reporting and Data System.
PubMed 文献 · Eur J Radiol · 2021-02-06

回顾性纳入821例芬兰东部乳腺癌女性(平均年龄62.8±12.2岁),半自动及两名放射科医生视觉评估数字乳腺X线,按BI-RADS第4版与第5版分类。观察者间ICC为0.93,第4版下93.8%的乳腺癌发生于脂肪型乳腺;第5版使更致密分类整体增加,几乎完全脂肪型减少50.2%。

要点

  • 第4版BI-RADS下93.8%乳腺癌发生于脂肪型乳腺(面积密度<50%)
  • 第5版BI-RADS使更致密评估整体增加,几乎完全脂肪型减少50.2%
  • 视觉评估观察者间一致性极好,ICC为0.93

诊断标准与关键数值

  • 按BI-RADS第4版评估时,93.8%的乳腺癌发生于脂肪型乳腺,校正年龄和BMI后分布保持不变。
  • 使用第5版时,几乎完全脂肪型整体减少50.2%(p<0.001),散在纤维腺体型增加19.4%(p<0.001),不均匀致密型增加28.7%(p<0.001),极度致密型增加2.1%(p<0.001)。
  • 视觉评估观察者间可重复性极好,ICC为0.93。

局限性

  • 原文未报告局限性

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: To examine the breast density distribution in patients diagnosed with breast cancer in an eastern Finnish population and to examine the changes in breast density reporting patterns between the 4th and 5th editions of the Breast Imaging-Reporting and Data System (BI-RADS).

METHOD: 821 women (mean age 62.8 ± 12.2 years, range 28-94 years) with breast cancer were included in this retrospective study and their digital mammographic examinations were assessed semi-automatically and then visually by two radiologists in accordance with the 4th and 5th editions of the BI-RADS. Intraclass correlation coefficients (ICCs) were used to evaluate interobserver reproducibility. Chi-square tests were used to examine the associations between the breast density distribution and age or body mass index (BMI).

RESULTS: Interobserver reproducibility of the visual assessment was excellent, with an ICCr = 0.93. The majority of breast cancers occurred in fatty breasts (93.8 %) when density was assessed according to the 4th edition of the BI-RADS. The distributions remained constant after correction for age and BMI. Using the 5th edition, there was an overall 50.2 % decrease in almost entirely fatty (p < 0.001), 19.4 % increase in scattered fibroglandular (p < 0.001), 28.7 % increase in heterogeneously dense (p < 0.001), and 2.1 % increase in extremely dense (p < 0.001) categories.

CONCLUSIONS: Most breast cancers in eastern Finland occur in fatty breasts with an area density of < 50 %. Assessing breast density using the 5th edition of the BI-RADS greatly increased denser assessments.

来源:Eur J Radiol,查看原文。版权归原作者所有。

引用

  1. Nykänen A, Okuma H, Sutela A, et al. The mammographic breast density distribution of Finnish women with breast cancer and comparison of breast density reporting using the 4th and 5th editions of the Breast Imaging-Reporting and Data System. Eur J Radiol. 2021. PMID: 33607373. doi:10.1016/j.ejrad.2021.109585

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。