数字乳腺摄影持续提高高级别及总体DCIS检出率但未改变升级率
该回顾性研究纳入2001至2014年经乳腺X线钙化检出并诊断为DCIS的484例病例,比较胶片乳腺摄影(FSM)与数字乳腺摄影(DM)的检出率及DCIS升级为浸润癌的比例。DM检出率及高级别DCIS检出率均显著高于FSM,且DM持续检出优势在峰值后仍存在;但两种方法DCIS升级为浸润癌的比例无显著差异,多数升级病例来自高级别DCIS。
要点
- DM检出DCIS的检出率为1.4/1000,高于FSM的0.7/1000(p < .001)。
- DM检出高级别DCIS的检出率为0.8/1000,是FSM 0.4/1000的两倍(p < .001)。
- DM与FSM的DCIS升级为浸润癌比例均为10%,差异无统计学意义(p = .74)。
诊断标准与关键数值
- DM与FSM检出率分别为1.4/1000与0.7/1000(p < .001)。
- DM与FSM高级别DCIS检出率分别为0.8/1000与0.4/1000(p < .001)。
- DM检出的DCIS在2008年达到过峰2.7/1000,之后持续检出率为1.4/1000,仍为FSM 0.7/1000的两倍。
- DM与FSM的DCIS升级为浸润癌比例分别为10%(34/326)与10%(15/158),差异无统计学意义(p = .74)。
- 高级别DCIS占升级为浸润癌病例的71%(35/49)。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE. The purpose of this article is to evaluate whether digital mammography (DM) is associated with persistent increased detection of ductal carcinoma in situ (DCIS) or has altered the upgrade rate of DCIS to invasive cancer. MATERIALS AND METHODS. An institutional review board-approved retrospective search identified DCIS diagnosed in women with mammographic calcifications between 2001 and 2014. Ipsilateral cancer within 2 years, masses, papillary DCIS, and patients with outside imaging were excluded, yielding 484 cases. Medical records were reviewed for mammographic calcifications, technique, and pathologic diagnosis. Mammograms were interpreted by radiologists certified by the Mammography Quality Standards Act. The institution transitioned from film-screen mammography (FSM) to exclusive DM by 2010. Statistical analyses were performed using chi-square test. RESULTS. Of 484 DCIS cases, 158 (33%) were detected by FSM and 326 (67%) were detected by DM. The detection rate was higher with DM than FSM (1.4 and 0.7 per 1000, respectively; p < .001). The detection rate of high-grade DCIS doubled with DM compared with FSM (0.8 and 0.4 per 1000, respectively; p < .001). The prevalent peak of DM-detected DCIS was 2.7 per 1000 in 2008. Incident DM detection remained double FSM (1.4 vs 0.7 per 1000). Similar proportions of high-grade versus low- to intermediate-grade DCIS were detected with both modalities. There was no significant difference in the upgrade rate of DCIS to invasive cancer between DM (10%; 34/326) and FSM (10%; 15/158) (p = .74). High-grade DCIS led to 71% (35/49) of the upgrades to invasive cancer. CONCLUSION. DM was associated with a significant doubling in DCIS and high-grade DCIS detection, which persisted after prevalent peak. The majority of upgrades to invasive cancer arose from high-grade DCIS. DM was not associated with decreased upgrade to invasive cancer.
引用
- Neal CH, Joe AI, Patterson SK, et al. Digital Mammography Has Persistently Increased High-Grade and Overall DCIS Detection Without Altering Upgrade Rate. AJR Am J Roentgenol. 2021. PMID: 33594910. doi:10.2214/AJR.20.23314
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。