文献速递妇产影像MR

3.0T下缩减视野与常规视野扩散加权成像评估宫颈癌的图像质量与FIGO分期比较

Comparison of reduced field-of-view diffusion-weighted imaging (DWI) and conventional DWI techniques in the assessment of Cervical carcinoma at 3.0T: Image quality and FIGO staging.
PubMed 文献 · Eur J Radiol · 2021-01-21

回顾性分析60例病理证实宫颈癌患者,于3.0T MRI上同时行治疗前缩减视野(r-FOV)DWI和全视野(f-FOV)DWI。r-FOV DWI主观图像质量评分和对比噪声比显著高于f-FOV DWI,但信噪比显著低于f-FOV DWI,两者平均ADC值无显著差异。两种序列ADC值与FIGO分期均呈显著负相关。

要点

  • r-FOV DWI主观图像质量评分显著高于f-FOV DWI(P < 0.001)。
  • r-FOV DWI的CNR高于f-FOV DWI,但SNR低于f-FOV DWI。
  • 两种序列平均ADC值无显著差异,ADC值与FIGO分期均呈负相关。

关键影像表现/征象

  • r-FOV DWI的主观图像质量评分显著高于f-FOV DWI(P < 0.001)。
  • r-FOV DWI的对比噪声比(CNR)为10.30 ± 3.676,f-FOV DWI为8.91 ± 3.008,r-FOV DWI较f-FOV DWI升高(P = 0.021)。
  • r-FOV DWI的信噪比(SNR)为27.80 ± 6.056,f-FOV DWI为33.67 ± 7.833,r-FOV DWI较f-FOV DWI降低(P<0.001)。

诊断标准与关键数值

  • r-FOV DWI与f-FOV DWI的平均ADC值无显著差异。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: To evaluate imaging quality (IQ) and International Federation of Gynecology and Obstetrics (FIGO) staging of reduced field-of-view (r-FOV) diffusion-weighted imaging (DWI) in cervical carcinoma (CC).

MATERIALS AND METHODS: Sixty patients with pathologically proven CC who underwent both pre-treatment r-FOV DWI and full field-of-view (f-FOV) DWI on a 3.0T MRI scanner were retrospectively reviewed. The subjective qualitative image scores were compared using the Wilcoxon signed-rank test. Objective quality values and apparent diffusion coefficient (ADC) were estimated by paired t-test or Wilcoxon signed-rank test for the two DWI sequences according to Normality test. Spearman rank correlation analysis was used to evaluate the relationship between pathological results and mean ADC value.

RESULTS: The subjective IQ scores for r-FOV DWI were significantly higher than those for f-FOV DWI (P < 0.001). Similarly, the contrast-to-noise (CNR) value of r-FOV DWI was superior to that of f-FOV DWI (10.30 ± 3.676, 8.91 ± 3.008, P = 0.021). However, the signal-to-noise ratio (SNR) value of r-FOV DWI was considerably lower than that of f-FOV DWI (27.80 ± 6.056, 33.67 ± 7.833, P<0.001). No significant difference was found between mean ADC values of f-FOV DWI and r-FOV DWI. There was a significant tendency for a negative correlation between the ADC values and FIGO stages of CC for both two sequences (r=-0. 436, P<0.01; r=-0.470, P<0.01, respectively).

CONCLUSIONS: The rFOV DWI sequence provided significantly better IQ and lesion conspicuity than the fFOV DWI sequence. In addition, rFOV sequences can be used in evaluation of FIGO staging of cervical cancer.

来源:Eur J Radiol,查看原文。版权归原作者所有。

引用

  1. Chen M, Feng C, Wang Q, et al. Comparison of reduced field-of-view diffusion-weighted imaging (DWI) and conventional DWI techniques in the assessment of Cervical carcinoma at 3.0T: Image quality and FIGO staging. Eur J Radiol. 2021. PMID: 33549900. doi:10.1016/j.ejrad.2021.109557

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。