多参数经阴道超声诊断绝经后出血中的子宫内膜癌
纳入152例绝经后出血且子宫内膜厚度≥4 mm的女性,由两位有经验放射科医生实时评估灰阶超声、能量多普勒和凝胶灌注超声,另由两位经验较少医生离线分析视频片段。实时超声标准正确诊断95%的子宫内膜癌,诊断效率92%;排除低质量视频后,实时评估准确率96%与离线分析92%相当。结论认为技术良好时多参数实时超声可高准确度和可重复性地诊断子宫内膜癌。
要点
- 实时多参数超声标准(ET≥5 mm加上特定血流/内膜交界异常)正确诊断95%的子宫内膜癌。
- 排除低质量视频后,实时评估准确率96%与离线分析92%相当。
- 诊断标准在实时超声与离线分析之间显示出良好至极好的一致性。
关键影像表现/征象
- 灰阶超声和/或凝胶灌注超声显示子宫内膜厚度≥5 mm,伴不规则分支状内膜血管、多条血管穿过内膜或密集彩色斑点状血管区,且内膜-肌层交界不完整或中断。
诊断标准与关键数值
- 实时超声标准(ET≥5 mm伴不规则分支状内膜血管或多条血管穿过内膜或密集彩色斑点状血管区,且灰阶超声和/或GIS示内膜-肌层交界不完整或中断)正确诊断95%的子宫内膜癌,诊断效率92%。
临床应用与阅片要点
- 在绝经后出血且子宫内膜厚度≥4 mm的女性中,可综合灰阶超声、能量多普勒和凝胶灌注超声的多参数标准实时评估子宫内膜癌。
- 实时评估与离线视频分析之间诊断标准一致性良好至极好,经验较少观察者离线分析亦可行。
- 排除低质量视频后,实时评估准确率96%,离线分析准确率92%。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE: (a) To comparatively evaluate the performance of grayscale ultrasound features, power Doppler (PD) blood flow characteristics, and gel infusion sonography (GIS) in diagnosing endometrial cancer during real-time examination, (b) to compare the performance of real-time diagnosis of endometrial cancer by experienced observers with offline analysis by blinded observers using similar sonographic criteria during review of cine loop clips.
METHODS: 152 females with post-menopausal bleeding (PMB) had ET ≥ 4 mm at first-line ultrasound were included. Two experienced radiologists evaluated endometrial patterns at real-time evaluation (grayscale ultrasound, PD, and GIS), then examinations were stored as video clips for later evaluation by two less-experienced radiologists. The reference standard was hysteroscopy (HY) and/or hysterectomy with the histopathological examination. The area under (AUC) the receiver operating characteristic (ROC) curve was calculated to assess the diagnostic performance for the prediction of endometrial cancer.
RESULTS: Among 152 females with ET ≥ 4 mm at first line TVUS, 88 (57.9%) patients had endometrial cancer on final pathologic analysis. Real-time ultrasound criteria (ET ≥ 5 mm with the presence of irregular branching endometrial blood vessels or multiple vessels crossing EM or areas with densely packed color-splash vessels with non-intact or interrupted EMJ at the grayscale ultrasound and/or GIS) correctly diagnosed 95% of endometrial cancers with 92% diagnostic efficiency.There is comparable accuracy of real-time evaluation (96%) and offline analysis (92%) after the exclusion of poor quality videos from the analysis. The diagnostic criteria showed good to an excellent agreement between real-time ultrasound and offline analysis.
CONCLUSION: When real-time ultrasound is performed with good technique, utilizing multiple parameters, it is possible to diagnose endometrial cancer with a high degree of accuracy and reproducibility.
ADVANCES IN KNOWLEDGE: when real-time ultrasound is performed with good technique, utilizing multiple parameters, it is possible to diagnose endometrial cancer with a high degree of accuracy and reproducibility.
引用
- Abdalla S, Abou-Taleb H, Badary DM, et al. Multiparametric transvaginal ultrasound in the diagnosis of endometrial cancer in post-menopausal bleeding: diagnostic performance of a transvaginal algorithm and reproducibility amongst less experienced observers. Br J Radiol. 2021. PMID: 33529055. doi:10.1259/bjr.20201195
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。