文献速递妇产影像USMR

经阴道超声与磁共振成像术前评估低级别子宫内膜样癌的诊断效能:前瞻性对比研究

Diagnostic performance of transvaginal ultrasound and magnetic resonance imaging for preoperative evaluation of low-grade endometrioid endometrial carcinoma: prospective comparative study.
PubMed 文献 · Ultrasound Obstet Gynecol · 2021-01-01

前瞻性纳入2013年10月至2018年7月西班牙巴塞罗那Vall d'Hebron医院131例低级别子宫内膜样癌患者,术前分别行经阴道超声和磁共振成像评估深肌层浸润和宫颈间质浸润,以手术病理为参考标准。经阴道超声预测深肌层浸润和宫颈间质浸润的敏感度均高于磁共振成像,特异度相似或相同,两种方法一致指数分别为0.84和0.92。结论认为经阴道超声诊断效能与磁共振成像相似,可作为低级别子宫内膜样癌术前评估的一线影像技术。

要点

  • 经阴道超声预测深肌层浸润敏感度69%,磁共振成像51%,特异度分别为87%和91%。
  • 经阴道超声预测宫颈间质浸润敏感度43%,磁共振成像24%,两者特异度均为97%。
  • 两种方法一致指数深肌层浸润0.84、宫颈间质浸润0.92,诊断效能相似。

核心结论

  • 经阴道超声对低级别子宫内膜样癌深肌层浸润和宫颈间质浸润的预测效能与磁共振成像相似,经阴道超声可作为术前评估的一线影像技术。

研究设计与样本

  • 前瞻性研究,连续纳入2013年10月至2018年7月西班牙巴塞罗那Vall d'Hebron医院131例低级别(1级或2级)子宫内膜样癌患者。
  • 术前分别行经阴道超声和磁共振成像分期评估,随后行手术分期,以最终组织病理学为参考标准。
  • 计算两种影像技术预测深肌层浸润和宫颈间质浸润的敏感度、特异度、似然比和诊断准确率,并计算两种技术的一致指数,遵循STARD 2015指南。

诊断标准与关键数值

  • 经阴道超声预测深肌层浸润:敏感度69%(95%CI 53-82%),特异度87%(95%CI 78-93%)。
  • 磁共振成像预测深肌层浸润:敏感度51%(95%CI 36-66%),特异度91%(95%CI 82-96%)。
  • 经阴道超声预测宫颈间质浸润:敏感度43%(95%CI 27-61%),特异度97%(95%CI 91-99%)。
  • 磁共振成像预测宫颈间质浸润:敏感度24%(95%CI 12-41%),特异度97%(95%CI 91-99%)。
  • 经阴道超声与磁共振成像一致指数:深肌层浸润0.84(95%CI 0.76-0.90),宫颈间质浸润0.92(95%CI 0.85-0.96)。

临床应用与阅片要点

  • 经阴道超声预测深肌层浸润的敏感度高于磁共振成像(69% vs 51%),特异度相似(87% vs 91%)。
  • 经阴道超声预测宫颈间质浸润的敏感度高于磁共振成像(43% vs 24%),两者特异度相同(均为97%)。
  • 作者认为经阴道超声可作为低级别子宫内膜样癌术前评估的一线影像技术。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: To compare the diagnostic performance of transvaginal ultrasound (TVS) and magnetic resonance imaging (MRI) in the prediction of deep myometrial invasion (DMI) and cervical stromal invasion (CSI) in patients with low-grade (Grade 1 or 2) endometrioid endometrial cancer (EEC).

METHODS: This was a prospective study including all patients with low-grade EEC diagnosed between October 2013 and July 2018 at the Vall d'Hebron Hospital in Barcelona, Spain. Preoperative staging was performed using TVS and MRI, followed by surgical staging. Final histology was considered as the reference standard. Sensitivity, specificity, likelihood ratios and diagnostic accuracy were calculated for both imaging techniques in the prediction of DMI and CSI, and the agreement index was calculated for both techniques. The STARD 2015 guidelines were followed.

RESULTS: A total of 131 patients with low-grade EEC were included consecutively. Sensitivity was higher for TVS than for MRI both for the prediction of DMI (69% (95% CI, 53-82%) vs 51% (95% CI, 36-66%), respectively) and CSI (43% (95% CI, 27-61%) vs 24% (95% CI, 12-41%), respectively). Specificity was similar for TVS and MRI in the prediction of DMI (87% (95% CI, 78-93%) vs 91% (95% CI, 82-96%)) and equal in the prediction of CSI (97% (95% CI, 91-99%) for both). The agreement index between TVS and MRI was 0.84 (95% CI, 0.76-0.90) for DMI and 0.92 (95% CI, 0.85-0.96) for CSI.

CONCLUSIONS: The diagnostic performance of TVS is similar to that of MRI for the prediction of DMI and CSI in low-grade EEC, and TVS can play a role as a first-line imaging technique in the preoperative evaluation of low-grade EEC. © 2021 International Society of Ultrasound in Obstetrics and Gynecology.

来源:Ultrasound Obstet Gynecol,查看原文。版权归原作者所有。

引用

  1. Cubo-Abert M, Díaz-Feijoo B, Bradbury M, et al. Diagnostic performance of transvaginal ultrasound and magnetic resonance imaging for preoperative evaluation of low-grade endometrioid endometrial carcinoma: prospective comparative study. Ultrasound Obstet Gynecol. 2021. PMID: 33533532. doi:10.1002/uog.23607

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。