子宫动脉栓塞治疗子宫肌瘤:体积反应的MRI预测特征
该回顾性研究纳入2013年8月至2018年12月间成功治疗的75例患者共212个子宫肌瘤,评估MRI特征对子宫动脉栓塞后体积反应的预测价值。黏膜下位置、T2WI高信号、基线肌瘤体积小(<58 cm3)及减影成像高信号为独立有利预测因素,五变量ROC模型AUC为0.85、敏感度82%、特异度71%。
要点
- 黏膜下位置是肌瘤体积反应最佳预测因素,较非黏膜下位置多32.2%体积反应(p<.001)。
- T2WI高信号肌瘤较T2WI低信号肌瘤多16.9%体积反应(p=.013)。
- 五变量ROC模型预测至少40%肌瘤体积反应的AUC为0.85,敏感度82%,特异度71%。
关键影像表现/征象
- 黏膜下位置肌瘤较非黏膜下位置多32.2%肌瘤体积反应(p<.001)。
- T2WI高信号肌瘤较T2WI低信号肌瘤多16.9%体积反应(p=.013)。
- 基线肌瘤体积小(<58 cm3)者较大体积肌瘤多10.2%体积反应(p=.01)。
- 减影成像高信号肌瘤较低信号肌瘤多7.9%体积反应(p=.014)。
诊断标准与关键数值
- 五变量ROC模型(T2WI信号强度比、强化率、T2WI不均匀性比率、位置、基线肌瘤体积)预测至少40%肌瘤体积反应:AUC 0.85,敏感度82%,特异度71%。
- 年龄、肌瘤数目、基线子宫体积对子宫体积反应无预测价值。
临床应用与阅片要点
- 阅片时可关注肌瘤位置(黏膜下vs非黏膜下)、T2WI信号(高信号vs低信号)、基线体积(<58 cm3)及减影成像信号(高信号vs低信号),这些特征与UAE后体积反应相关。
- 作者认为该五变量ROC模型可能有助于筛选适合UAE的患者。
- 作者建议进一步研究采用纹理分析和影像组学定量评估T2WI不均匀性作为体积反应预测因素。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE. The purpose of this article was to evaluate MRI features of uterine leiomyomas that predict volumetric response after uterine artery embolization (UAE). MATERIALS AND METHODS. This retrospective study included 75 patients with 212 uterine leiomyomas who were successfully treated between August 2013 and December 2018. To predict uterine volumetric response, age, number of lesions, and baseline uterine volume were assessed. To predict leiomyoma volumetric response, a multivariate regression analysis was performed to evaluate six predictive factors: location, baseline leiomyoma volume, signal intensity on T1-weighted and T2-weighted MRI, heterogeneity of signal intensity on T2-weighted MRI, and vascularity on subtraction imaging (SI). A five-variable predictive ROC model was developed to evaluate the diagnostic accuracy of the signal intensity ratio on T2-weighted MRI, enhancement ratio, heterogeneity ratio on T2-weighted MRI, location, and baseline leiomyoma volume in predicting at least 40% leiomyoma volumetric response. RESULTS. Age, number of leiomyomas, and baseline uterine volume were not predictive of uterine volumetric response. A submucosal location was the best predictive factor of leiomyoma volumetric response, and it showed 32.2% more leiomyoma volumetric response compared with a nonsubmucosal location (p < .001). Hyperintensity on T2-weighted MRI was the second best predictive factor of leiomyoma volumetric response, and it showed 16.9% more volumetric response compared with hypointense leiomyomas (p = .013). A small baseline leiomyoma volume (< 58 cm3) was associated with 10.2% more leiomyoma volumetric response compared with larger leiomyomas (p = .01). Leiomyomas that were hyperintense on SI showed 7.9% more leiomyoma volumetric response compared with those that were hypointense (p = .014). The five-variable ROC model showed high diagnostic accuracy with an AUC of 0.85, sensitivity of 82%, and specificity of 71%. CONCLUSION. A submucosal location, hyperintensity on T2-weighted MRI, small baseline leiomyoma volume (< 58 cm3), and hyperintense leiomyoma on subtraction imaging are the main independent favorable predictors of leiomyoma volumetric response after UAE. An accurate predictive ROC model was developed that may help in selecting patients suitable for UAE. Quantitative assessment of heterogeneity on T2-weighted MRI showed promising results as a predictor of volumetric response, and further research in this area using texture analysis and radiomics is suggested.
引用
- Kurban LAS, Metwally H, Abdullah M, et al. Uterine Artery Embolization of Uterine Leiomyomas: Predictive MRI Features of Volumetric Response. AJR Am J Roentgenol. 2021. PMID: 33594913. doi:10.2214/AJR.20.22906
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。