文献速递泌尿生殖技术与安全US

声辐射力脉冲成像测量肾实质硬度的技术性能:系统评价与Meta分析

Technical Performance of Acoustic Radiation Force Impulse Imaging for Measuring Renal Parenchymal Stiffness: A Systematic Review and Meta-Analysis.
PubMed 文献 · J Ultrasound Med · 2021-02-18

该系统评价与Meta分析纳入24项研究共2993例患者,评估声辐射力脉冲成像(含二维剪切波弹性成像与点剪切波弹性成像)测量肾实质硬度的技术失败率及观察者间/观察者内一致性。 native肾与移植肾的技术失败率分别为4.3%与6.6%,观察者间ICC分别为0.70与0.81,native肾观察者内ICC为0.77;作者结论认为该技术整体技术性能良好,但剪切波弹性成像协议差异大,需制定标准化指南。

要点

  • native肾技术失败率4.3%,移植肾6.6%。
  • 观察者间ICC:native肾0.70,移植肾0.81。
  • 移植肾观察者间异质性因素为ROI位置(仅中极 vs 其他,P=.04)。

诊断标准与关键数值

  • native肾技术失败合并比例4.3%(95%CI 2.2-8.5%),移植肾6.6%(95%CI 4.0-10.7%)。
  • 观察者间一致性ICC:native肾0.70(95%CI 0.68-0.83),为中等一致性;移植肾0.81(95%CI 0.68-0.89),为良好一致性。
  • native肾观察者内一致性ICC为0.77(95%CI 0.49-0.91),为良好一致性。

临床应用与阅片要点

  • 移植肾观察者间一致性分析中,ROI位置(仅中极 vs 其他)是异质性的显著因素(P = .04)。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: To estimate the technical performance of acoustic radiation force impulse (ARFI) imaging (two-dimensional shear wave elastography [2D-SWE] and point shear wave elastography [p-SWE]) for measuring renal parenchymal stiffness.

METHODS: EMBASE and PubMed databases were searched for studies reporting technical performance of ARFI imaging in terms of technical failure, interobserver agreement, and/or intraobserver agreement. The proportion of technical failure and intraclass correlation coefficients (ICCs) for interobserver and intraobserver agreement was pooled. The pooled estimates of native and transplanted kidneys were obtained separately. Meta-regression and subgroup analyses were conducted to explore heterogeneity.

RESULTS: Twenty-four studies (2993 patients) were included. The pooled proportions of technical failure were 4.3% (95% confidence interval [CI] 2.2-8.5%) and 6.6% (95% CI 4.0-10.7%) in native and transplanted kidneys, respectively. The pooled ICCs of interobserver agreement were 0.70 (95% CI 0.68-0.83) and 0.81 (95% CI 0.68-0.89), indicating moderate and good agreement in native and transplanted kidneys, respectively. The pooled ICC showed good (0.77; 95% CI 0.49-0.91) intraobserver agreement in native kidneys. Regarding interobserver agreement in transplanted kidneys, ROI location (mid pole only versus others) was a significant factor of heterogeneity (P = .04).

CONCLUSIONS: The ARFI-based SWE techniques show good technical performance for measuring renal parenchymal stiffness. The wide range of SWE protocols necessitates development of standardized guidelines on the use of renal ARFI imaging.

来源:J Ultrasound Med,查看原文。版权归原作者所有。

引用

  1. Hwang J, Kim HW, Kim PH, et al. Technical Performance of Acoustic Radiation Force Impulse Imaging for Measuring Renal Parenchymal Stiffness: A Systematic Review and Meta-Analysis. J Ultrasound Med. 2021. PMID: 33599306. doi:10.1002/jum.15654

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。