文献速递泌尿生殖腹部MR

DCE-MRI与DWI评估肌层浸润性膀胱癌新辅助化疗后肿瘤反应的诊断效能

Diagnostic performance of contrast-enhanced dynamic and diffusion-weighted MR imaging in the assessment of tumor response to neoadjuvant therapy in muscle-invasive bladder cancer.
PubMed 文献 · Abdom Radiol (NY) · 2021-02-06

本前瞻性研究纳入90例完成新辅助化疗的肌层浸润性膀胱癌患者,由两名放射科医生独立测量DCE-MRI半定量参数(流入率、流出率)及ADC值。病理完全缓解率为43.3%(39/90),流出率与ADC值联合预测病理完全缓解的敏感度、特异度分别为95.4%、97.7%(读者1)和96%、97%(读者2),AUC分别为0.981和0.971。

要点

  • ADC值截断值0.911×10⁻³mm²/s、流出率截断值0.677 min⁻¹联合预测病理完全缓解AUC达0.981(读者1)。
  • 病理完全缓解与流出率(r=-0.701,p=0.01)及ADC值(r=-0.621,p=0.01)呈负相关。
  • ADC值与流出率测量可重复性优良,ICC分别为0.89(95%CI 0.84-0.89)和0.87(95%CI 0.86-0.91)。

诊断标准与关键数值

  • ADC值截断值0.911×10⁻³mm²/s预测病理完全缓解的诊断准确率为读者1 92%、读者2 91%。
  • 流出率截断值0.677 min⁻¹预测病理完全缓解的诊断准确率为读者1 90%、读者2 88%。
  • ADC值联合流出率截断值预测病理完全缓解的敏感度、特异度分别为读者1 95.4%、97.7%,读者2 96%、97%。
  • ADC值联合流出率截断值预测病理完全缓解的AUC为读者1 0.981、读者2 0.971。
  • ADC值测量ICC为0.89(95%CI 0.84-0.89),流出率测量ICC为0.87(95%CI 0.86-0.91),总体可重复性ICC=0.83-0.90。

临床应用与阅片要点

  • 作者认为DCE-MRI流出率与ADC值联合使用可提供识别肌层浸润性膀胱癌新辅助化疗后病理完全缓解的最佳可能。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: To evaluate the diagnostic performance of DCE MRI and DWI in the assessment of pathologic complete response (pCR) after neoadjuvant chemotherapy (NAC) in patients with muscle-invasive bladder cancer (MIBC).

METHODS: This prospective study included 90 patients with MIBC who finished NAC. Two radiologists independently assessed MRI for the determination of semi-quantitative parameters (wash-in rate and wash-out rate) and apparent diffusion coefficient (ADC) value. The correlation between pCR and wash-in rate, wash-out rate, ADC value were analyzed. The area under the ROC curve (AUC) was used to evaluate the diagnostic performance for detecting pCR. Inter-reader agreement was assessed using the ICC statistics.

RESULTS: On cystectomy specimens, pCR was confirmed in (43.3%, 39/90). pCR is negatively correlated with wash-out rate (r = - 0.701, p = 0.01) and ADC value (r = - 0.621, p = 0.01). ADC value is positively correlated with wash-out rate (r = 0.631, p = 0.001). The diagnostic accuracy of ADC value (cut-off value: 0.911 × 10-3mm2/s) and wash-out rate (cut-off value: 0.677 min-1) in the identification of pCR was (92% for reader 1, 91% for reader 2), and (90% for reader 1, 88% for reader 2), respectively. The sensitivity, specificity for predicting pCR using ADC value + washout rate cut off values were 95.4%, 97.7% for reader 1, and 96%, 97% for reader 2, respectively. AUC was 0.981 for reader 1, 0.971 for reader 2. The overall reproducibility of the mean ADC value and wash out rate was excellent (ICC = 0.83-0.90). The ICC values for the mean ADC value, washout rate was 0.89 (95% CI 0.84-0.89) and 0.87 (95% CI 0.86-0.91), respectively.

CONCLUSION: Semi-quantitative parameter (wash-out) derived from DCE-MRI and ADC has the potential to assess the tumor's complete pathologic response. The two parameters using together can offer the best possibility to identify complete response to NAC in MIBC.

来源:Abdom Radiol (NY),查看原文。版权归原作者所有。

引用

  1. Ahmed SA, Taher MGA, Ali WA, et al. Diagnostic performance of contrast-enhanced dynamic and diffusion-weighted MR imaging in the assessment of tumor response to neoadjuvant therapy in muscle-invasive bladder cancer. Abdom Radiol (NY). 2021. PMID: 33547919. doi:10.1007/s00261-021-02963-7

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。