文献速递泌尿生殖腹部MR

深度学习加速前列腺T2加权成像:缩短采集时间并提升图像质量

Deep learning-accelerated T2-weighted imaging of the prostate: Reduction of acquisition time and improvement of image quality.
PubMed 文献 · Eur J Radiol · 2021-02-15

这项回顾性研究纳入30例因疑似前列腺癌行多参数MRI的患者,比较深度学习T2加权TSE序列(T2DL)与标准T2加权TSE序列(T2S)。T2DL轴位采集时间1:38 min,较T2S的4:37 min缩短65%;两位阅片者均认为T2DL噪声与整体图像质量更优(中位4分 vs 3分,均p<0.001),病灶可检出性也更高,而PI-RADS评分无差异、不影响患者管理。

要点

  • T2DL轴位采集时间1:38 min,较T2S的4:37 min缩短65%。
  • 两位阅片者均评T2DL噪声与整体图像质量中位4分,优于T2S的3分(均p<0.001)。
  • T2DL病灶可检出性中位4分,高于T2S的3分(p=0.005与<0.001),PI-RADS评分无差异。

关键影像表现/征象

  • T2DL噪声水平与整体图像质量被两位阅片者评为显著更优,中位4分,T2S中位3分(均p<0.001)。
  • T2DL病灶可检出性两位阅片者均评更高,中位4分,T2S中位3分(p=0.005与<0.001)。
  • T2DL与T2S的PI-RADS评分无差异,不影响患者管理。

诊断标准与关键数值

  • 图像质量、病灶可检出性与诊断信心采用1至4分Likert量表,4分为最佳。
  • 对最恶性病灶记录T2评分与PI-RADS评分。

临床应用与阅片要点

  • T2DL轴位采集时间1:38 min,较T2S的4:37 min缩短65%,可减少检查时间。
  • 两位阅片者均认为T2DL图像质量与病灶可检出性更优,PI-RADS评分无差异。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: To introduce a novel deep learning (DL) T2-weighted TSE imaging (T2DL) sequence in prostate MRI and investigate its impact on examination time, image quality, diagnostic confidence, and PI-RADS classification compared to standard T2-weighted TSE imaging (T2S).

METHOD: Thirty patients who underwent multiparametric MRI (mpMRI) of the prostate due to suspicion of prostatic cancer were included in this retrospective study. Standard sequences were acquired consisting of T1- and T2-weighted imaging and diffusion-weighted imaging as well as the novel T2DL. Axial acquisition time of T2S was 4:37 min compared to 1:38 min of T2DL. Two radiologists independently evaluated all imaging datasets in a blinded reading regarding image quality, lesion detectability, and diagnostic confidence using a Likert-scale ranging from 1 to 4 with 4 being the best. T2 score as well as PI-RADS score were obtained for the most malignant lesion.

RESULTS: Mean patient age was 65 ± 11 years. Noise levels and overall image quality were rated significantly superior by both readers with a median of 4 in T2DL compared to a median of 3 in T2S (all p < 0.001). Lesion detectability was also rated higher in T2DL by both readers with a median of 4 versus a median of 3 in T2S (p = 0.005 and <0.001, respectively). There was no difference regarding PI-RADS scoring between T2DL and T2S affecting patient management.

CONCLUSIONS: Deep learning axial T2w TSE imaging of the prostate is feasible with reduction of examination time of 65 % compared to standard imaging and improvement of image quality and lesion detectability.

来源:Eur J Radiol,查看原文。版权归原作者所有。

引用

  1. Gassenmaier S, Afat S, Nickel D, et al. Deep learning-accelerated T2-weighted imaging of the prostate: Reduction of acquisition time and improvement of image quality. Eur J Radiol. 2021. PMID: 33610853. doi:10.1016/j.ejrad.2021.109600

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。