慢性肾脏病的超声影像组学特征
本研究对75例慢性肾脏病患者和27例健康受试者的B型超声图像提取465个影像组学特征,用随机森林筛选最重要特征并训练支持向量机。小波变换的灰度游程矩阵归一化游程长度非均匀性(WT(LH)GRLN)区分CKD与健康肾脏的准确率为0.85、敏感度为1.0,健康肾脏该特征均值0.40±0.01显著高于CKD肾脏的0.24±0.01(p<0.01)。
要点
- 小波变换纹理特征WT(LH)GRLN在CKD与健康肾脏间差异显著(p<0.01)。
- 该特征区分CKD与健康肾脏的准确率0.85、敏感度1.0。
- 肾脏长轴垂直于图像矩阵列时该特征区分度最高。
关键影像表现/征象
- 健康肾脏的WT(LH)GRLN均值为0.40±0.01,显著高于CKD肾脏的0.24±0.01(p<0.01)。
- 根据Gini指数,肾脏长轴垂直于图像矩阵列方向时WT(LH)GRLN的区分度最高。
诊断标准与关键数值
- WT(LH)GRLN区分CKD与健康肾脏的准确率为0.85,敏感度为1.0。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
RATIONALE AND OBJECTIVES: Interstitial fibrosis, common to most chronic kidney diseases, can potentially affect the speckle patterns of kidney ultrasound (US). Here we use Radiomics features derived from US images to identify kidneys with chronic kidney disease.
MATERIALS AND METHODS: B-mode US without speckle reduction was performed on a cohort of CKD patients (n = 75) and healthy subjects (n = 27). Images of the patients with renal cysts, agenesis and calculi were excluded. After background subtraction, regions of interest were selected from each kidney. Four hundred and sixty-five Radiomics features including first and second-order gray level statistics were calculated on the selected regions. Second-order features were also calculated on wavelet transformed images. A random forest model was used to identify the most important features that can differentiate healthy and diseased kidneys. The ten most important features, based on the Gini index, were used to train a support vector machine. Synthetic minority oversampling technique was used to remove over fitting.
RESULTS: Wavelet transformed, Gray Level Run Length Matrix based Normalized Run Length Non-uniformity, WT (LH) (GRLN) was identified as the most significant feature in differentiating CKD and healthy kidneys (accuracy - 0.85, sensitivity - 1.0). The mean WT (LH) GRLN of healthy kidneys (0.40 ± 0.01) was significantly higher (p < 0.01) than that of the CKD kidneys (0.24 ± 0.01). According to the Gini Index, the differentiability of WT (LH) GRLN was highest when the long axis of the kidney was oriented perpendicular to the columns of the image matrix.
CONCLUSION: Radiomics features based on wavelet transformation are sensitive to directionality of US speckle patters and can be successfully used to differentiate CKD and healthy US kidney images.
引用
- Bandara MS, Gurunayaka B, Lakraj G, et al. Ultrasound Based Radiomics Features of Chronic Kidney Disease. Acad Radiol. 2021. PMID: 33589307. doi:10.1016/j.acra.2021.01.006