全变分正则化期望最大化重建对68Ga-PSMA PET图像质量的影响:体模与患者研究

Impact of total variation regularized expectation maximization reconstruction on the image quality of 68Ga-PSMA PET: a phantom and patient study.
PubMed 文献 · Br J Radiol · 2021-02-16

本研究利用含小热球插件的体模和20例前列腺癌患者,比较OSEM与TVREM(7种惩罚因子0.01–0.42,每床位2和3分钟采集)对68Ga-PSMA-11 PET/CT图像质量的影响。TVREM在惩罚因子0.07–0.28时对比度恢复、背景变异性和图像噪声均优于OSEM 3分钟组(均p<0.05),并允许缩短采集时间而保持图像质量。

要点

  • TVREM惩罚因子0.07–0.28时,2分钟/床位采集的对比度恢复、背景变异性和噪声优于OSEM 3分钟/床位。
  • TVREM惩罚因子0.14(2分钟/床位)和0.07(3分钟/床位)的肝脏噪声与OSEM 3分钟/床位相当,病灶SUVmax分别增加15%和20%。
  • TVREM 2分钟/床位组最高主观评分在惩罚因子0.21(3.30±0.66),3分钟/床位组在0.14(3.80±0.41),后者不低于OSEM组(2.90±0.45,p=0.2和p<0.001)。

关键影像表现/征象

  • 体模小热球插件的对比度恢复和背景变异性用于评估重建性能。
  • 肝脏图像噪声和病灶SUVmax为患者图像评估指标。
  • 主观图像质量采用5分制(1分差,5分优)由两名放射科医师评分。

诊断标准与关键数值

  • TVREM 2分钟/床位组在惩罚因子0.07–0.28时,对比度恢复、背景变异性、图像噪声及SUVmax增益均高于OSEM 3分钟/床位组(均p<0.05)。
  • OSEM 3分钟/床位组的图像噪声与TVREM 2分钟/床位(惩罚因子0.14)和3分钟/床位(惩罚因子0.07)组相当,同时病灶SUVmax分别增加15%和20%。
  • TVREM 2分钟/床位组最高主观评分在惩罚因子0.21(3.30±0.66);3分钟/床位组最高评分在惩罚因子0.14(3.80±0.41),等于或大于OSEM 3分钟/床位组(2.90±0.45,p=0.2和p<0.001)。

临床应用与阅片要点

  • TVREM重建结合优化惩罚因子可提升PSMA PET图像质量,并允许缩短每床位采集时间。
  • 惩罚因子0.07–0.28范围内TVREM在2分钟/床位采集时性能优于OSEM 3分钟/床位。
  • 主观评分在TVREM 3分钟/床位(惩罚因子0.14)不低于OSEM 3分钟/床位。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: To investigate the impact of total variation regularized expectation maximization (TVREM) reconstruction on the image quality of 68Ga-PSMA-11 PET/CT using phantom and patient data.

METHODS: Images of a phantom with small hot sphere inserts and 20 prostate cancer patients were acquired with a digital PET/CT using list-mode and reconstructed with ordered subset expectation maximization (OSEM) and TVREM with seven penalisation factors between 0.01 and 0.42 for 2 and 3 minutes-per-bed (m/b) acquisition. The contrast recovery (CR) and background variability (BV) of the phantom, image noise of the liver, and SUVmax of the lesions were measured. Qualitative image quality was scored by two radiologists using a 5-point scale (1-poor, 5-excellent).

RESULTS: The performance of CR, BV, and image noise, and the gain of SUVmax was higher for TVREM 2 m/b groups with the penalization of 0.07 to 0.28 compared to OSEM 3 m/b group (all p < 0.05). The image noise of OSEM 3 m/b group was equivalent to TVREM 2 and 3 m/b groups with a penalization of 0.14 and 0.07, while lesions' SUVmax increased 15 and 20%. The highest qualitative score was attained at the penalization of 0.21 (3.30 ± 0.66) for TVREM 2 m/b groups and the penalization 0.14 (3.80 ± 0.41) for 3 m/b group that equal to or greater than OSEM 3 m/b group (2.90 ± 0.45, p = 0.2 and p < 0.001).

CONCLUSIONS: TVREM improves lesion contrast and reduces image noise, which allows shorter acquisition with preserved image quality for PSMA PET/CT.

ADVANCES IN KNOWLEDGE: TVREM reconstruction with optimized penalization factors can generate higher quality PSMA-PET images for prostate cancer diagnosis.

来源:Br J Radiol,查看原文。版权归原作者所有。