文献速递腹部MR

深度学习超分辨率重建用于上腹部MRI:图像质量、诊断信心与病灶显著性的分析

Deep Learning-Based Superresolution Reconstruction for Upper Abdominal Magnetic Resonance Imaging: An Analysis of Image Quality, Diagnostic Confidence, and Lesion Conspicuity.
PubMed 文献 · Invest Radiol · 2021-01-01

该研究纳入46例上腹部病变患者,在1.5T下采集增强前后T1加权VIBE原始数据,用深度学习原型算法行去模糊、去噪和锐化重建(VIBESR),并与标准VIBESD图像盲法对照。结果显示VIBESR在整体图像质量、器官边界清晰度、血管锐利度、噪声、伪影、诊断信心及肝病灶锐利度和显著性上均显著优于VIBESD(P<0.001或P<0.01),病灶大小测量无显著差异。

要点

  • VIBESR重建在增强前后图像的整体质量、器官边界和血管锐利度上均显著优于VIBESD(P<0.001)。
  • VIBESR的噪声和伪影显著少于VIBESD,诊断信心显著更高(P<0.001)。
  • 28个肝病灶的锐利度和显著性在VIBESR上显著更好(P<0.01),但病灶大小测量无显著差异。

关键影像表现/征象

  • VIBESR增强前后图像的整体图像质量、器官边界解剖清晰度和血管锐利度均显著高于VIBESD(P<0.001)。
  • VIBESR图像的噪声和伪影显著少于VIBESD(P<0.001)。
  • 28个肝病灶中,VIBESR增强前后图像的病灶锐利度和显著性均显著优于VIBESD(P<0.01)。
  • 病灶最大径在增强前后VIBESD与VIBESR之间均无显著差异,两名读者对病灶大小的读者间一致性极好(组内相关系数>0.9)。

诊断标准与关键数值

  • 整体图像质量、器官边界解剖清晰度、血管锐利度、伪影、噪声、诊断信心及病灶锐利度和显著性均采用4点Likert等级评分。
  • 读者间一致性:增强前分析Cohen κ=0.72,增强后分析κ=0.74。
  • 事后回归分析显示,病灶锐利度/显著性每增加1分,VIBESR相对于VIBESD的比值比为13倍至17倍(P<0.001)。

临床应用与阅片要点

  • VIBESR重建可用于增强前后上腹部VIBE MRI,以提升图像质量、诊断信心和肝病灶显著性。
  • VIBESR与VIBESD在病灶大小测量上无显著差异,读者间一致性极好(组内相关系数>0.9)。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: The aim of this study was to investigate the impact of a deep learning-based superresolution reconstruction technique for T1-weighted volume-interpolated breath-hold examination (VIBESR) on image quality in comparison with standard VIBE images (VIBESD).

METHODS: Between May and August 2020, a total of 46 patients with various abdominal pathologies underwent contrast-enhanced upper abdominal VIBE magnetic resonance imaging (MRI) at 1.5 T. After data acquisition, the precontrast and postcontrast T1-weighted VIBE raw data were processed by a deep learning-based prototype algorithm for deblurring and denoising the images as well as for enhancing their sharpness (VIBESR). In a randomized and blinded manner, 2 radiologists independently analyzed the image data sets using the unprocessed images VIBESD as a standard reference. Outcome measures were as follows: overall image quality, anatomic clarity of organ borders, sharpness of vessels, artifacts, noise, and diagnostic confidence. All ratings were performed on an ordinal 4-point Likert scale. If the MRI examination encompassed a hepatic lesion, the maximum diameter of the largest hepatic lesion was quantified, and lesion sharpness and conspicuity were evaluated on an ordinal 4-point Likert scale. In addition, a post hoc regression analysis for lesion evaluation was computed. Finally, interrater/intrarater agreement was analyzed.

RESULTS: The overall image quality, anatomic clarity of organ borders, and sharpness of vessels in both precontrast and postcontrast images were rated significantly higher in VIBESR than in VIBESD (P < 0.001). Similarly, diagnostic confidence was higher in VIBESR than in VIBESD (P < 0.001). Furthermore, VIBESR images were rated to have significantly less noise and fewer artifacts in comparison with VIBESD (P < 0.001). The interreader agreement was substantial with a Cohen κ of 0.72 for the precontrast analysis and a κ of 0.74 for the postcontrast analysis. A total of 28 hepatic lesions were analyzed. For both readers, lesion sharpness and conspicuity were rated significantly better in VIBESR than in VIBESD in both the precontrast and postcontrast data sets (P < 0.01), which was consistent with the post hoc regression analysis (for every 1-point increase in sharpness/conspicuity, the odds ratio revealed a positive relation with VIBESR of 13-fold to 17-fold in comparison with VIBESD; P < 0.001). In terms of lesion size, there was no significant difference between the precontrast VIBESD and VIBESR or between the postcontrast VIBESD and VIBESR for both readers. Similarly, there was an excellent interreader agreement regarding lesion size (intraclass correlation coefficient, >0.9).

CONCLUSIONS: The data-driven superresolution reconstruction (VIBESR) is clinically feasible for precontrast and postcontrast upper abdominal VIBE MRI, providing improved image quality, diagnostic confidence, and lesion conspicuity compared with standard VIBESD images.

来源:Invest Radiol,查看原文。版权归原作者所有。

引用

  1. Almansour H, Gassenmaier S, Nickel D, et al. Deep Learning-Based Superresolution Reconstruction for Upper Abdominal Magnetic Resonance Imaging: An Analysis of Image Quality, Diagnostic Confidence, and Lesion Conspicuity. Invest Radiol. 2021. PMID: 33625063. doi:10.1097/RLI.0000000000000769