双层光谱探测器CT无创评估肝纤维化
本研究纳入68例肝移植或肝切除术前患者,采用双层光谱探测器CT平衡期测量肝实质碘密度与CT-ECV,分析其与纤维化分期的相关性及诊断效能。两位阅片者的I-ratio与CT-ECV均随纤维化分期进展而升高,CT-ECV鉴别F4期的AUC达0.884和0.925。结论认为平衡期肝实质碘密度与CT-ECV有助于预测高分期肝纤维化。
要点
- CT-ECV鉴别F4期AUC为0.884和0.925,优于I-ratio。
- 两位阅片者CT-ECV诊断F4期阈值分别为26.2%和29.3%。
- 平衡期肝实质碘密度与CT-ECV均随纤维化分期进展而升高。
诊断标准与关键数值
- CT-ECV诊断F4期阈值:阅片者1为26.2%,敏感度95.0%、特异度72.9%;阅片者2为29.3%,敏感度90.0%、特异度85.4%。
- CT-ECV鉴别F4期AUC:阅片者1为0.884,阅片者2为0.925。
- I-ratio与纤维化分期相关性:阅片者1 rho=0.380,阅片者2 rho=0.443,均p<0.01。
- CT-ECV与纤维化分期相关性:阅片者1 rho=0.423,阅片者2 rho=0.469,均p<0.01。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: To elucidate the diagnostic ability of liver fibrosis using (1) liver parenchymal iodine density on equilibrium computed tomographic imaging and (2) extracellular volume (ECV) measured by dual-layer spectral detector CT.
METHODS: From April 2018 to June 2019, 68 patients [mean age, 62 years; 39 males, 29 females] underwent dynamic contrast-enhanced CT by a dual-layer spectral detector CT system before liver transplantation or liver resection. The iodine densities of liver parenchyma (I liver) and aorta (I aorta) were independently measured by two radiologists at the equilibrium phase. The iodine-density ratio (I-ratio) (I liver/ I aorta) and the CT-ECV were calculated. Spearman's rank correlation coefficient was used to analyze the relationship between the I-ratio or the CT-ECV and the fibrosis stage. A receiver operating characteristic (ROC) curve analysis was performed to determine the accuracy of the I-ratio and the CT-ECV for discriminating fibrosis stages.
RESULTS: For both readers, the I-ratio and the CT-ECV increased significantly as the fibrosis stage advanced (I-ratio: rho = 0.380 and 0.443, p < 0.01; CT-ECV: rho = 0.423 and 0.469, p < 0.01). The CT-ECV showed better diagnostic accuracy for staging fibrosis, and the area under the ROC curve values for discriminating F4 stage were 0.884 and 0.925. The two readers' cutoff values of the CT-ECV for diagnosing fibrosis as F4 were 26.2 % and 29.3 %, with 95.0 % and 90.0 % sensitivity and 72.9 % and 85.4 % specificity, respectively.
CONCLUSION: The liver parenchymal iodine density on the equilibrium phase and the CT-ECV can be useful for predicting a high stage of liver fibrosis.
引用
- Morita K, Nishie A, Ushijima Y, et al. Noninvasive assessment of liver fibrosis by dual-layer spectral detector CT. Eur J Radiol. 2021. PMID: 33548853. doi:10.1016/j.ejrad.2021.109575
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。