肝细胞腺瘤亚型的18F-FDG PET/CT表现及文献综述

18F-FDG PET/CT of hepatocellular adenoma subtypes and review of literature.
PubMed 文献 · Abdom Radiol (NY) · 2021-02-08

本研究回顾性分析经病理证实的肝细胞腺瘤(HCA)患者的18F-FDG PET/CT影像特征,共纳入9例,其中7例明确亚型(4例HNF1A突变型,3例炎症型)。HNF1A突变型HCA的SUVmax、病灶/肝脏SUVmax比值及SUVmean均显著高于炎症型。作者认为HNF1A突变型HCA可能具有更高的SUV值,但文献数据存在矛盾,需进一步研究。

要点

  • HNF1A突变型HCA的SUVmax、病灶/肝脏比值及SUVmean均高于炎症型。
  • HNF1A突变型HCA的病灶/肝脏SUVmax比值平均为1.4,炎症型为0.8。
  • 作者认为HNF1A突变型HCA可能具有更高SUV值,但文献数据矛盾,需进一步研究。

关键影像表现/征象

  • HCA病灶平均大小2.8 cm(范围0.6-6.2,标准差2.0),平均SUVmax为5.9(范围2.1-18.9,标准差5.1)。
  • HNF1A突变型HCA的病灶SUVmax为5.3±1.48,炎症型为2.8±0.59,p<0.033。
  • HNF1A突变型HCA的病灶/肝脏SUVmax比值为1.4±0.22,炎症型为0.8±0.21,p=0.031。
  • HNF1A突变型HCA的病灶SUVmean为3.6±0.37,炎症型为2.0±0.46,p=0.0086。

诊断标准与关键数值

  • HNF1A突变型HCA的病灶SUVmax为5.3±1.48,炎症型为2.8±0.59(p<0.033)。
  • HNF1A突变型HCA的病灶/肝脏SUVmax比值为1.4±0.22,炎症型为0.8±0.21(p=0.031)。
  • HNF1A突变型HCA的病灶SUVmean为3.6±0.37,炎症型为2.0±0.46(p=0.0086)。

临床应用与阅片要点

  • 作者认为HNF1A突变型HCA可能具有比炎症型HCA更高的SUV值,但文献数据存在矛盾,需进一步研究。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

INTRODUCTION: This study evaluates 18F-FDG PET/CT imaging characteristics of pathologically proven hepatocellular adenoma (HCA) subtypes.

METHODS: This is a retrospective review of an institutional database (2011-2017) for subjects with a pathologic diagnosis of hepatic adenomas established within 6 months of a pre-treatment 18F-FDG PET/CT exam. An expert pathological review by a hepatopathologist was performed to confirm diagnosis and subtype HCA. A review of the 18F-FDG PET/CT exams was performed by two board-certified nuclear radiologists in consensus. Corresponding demographic and clinical data were obtained by electronic chart review.

RESULTS: Nine subjects were identified. An HCA subtype was established in seven subjects (4 HNF1A-mutated and 3 Inflammatory). The mean HCA lesion size was 2.8 cm (range 0.6-6.2, SD 2.0) with a mean SUVmax of 5.9 (range 2.1-18.9, SD 5.1). The SUV values of HNF1A-mutated HCA were significantly higher than inflammatory HCA: lesion SUVmax (5.3 ± 1.48 vs. 2.8 ± 0.59, p < 0.033), lesion-to-liver SUVmax ratio (1.4 ± 0.22 vs. 0.8 ± 0.21, p = 0.031), lesion SUVmean (3.6 ± 0.37 vs. 2.0 ± 0.46, p = 0.0086).

CONCLUSION: HNF1A-mutated HCA may have greater SUV values than inflammatory HCA on 18F-FDG PET/CT exams. However, there are contradictory data in the literature and further investigation is warranted.