双聚焦扫描法在先天性心脏病ECG门控CT心室容积测量中降低辐射剂量
本研究回顾性比较了先天性心脏病患者ECG门控CT心室容积测量中传统单次扫描与双聚焦扫描两种方法的辐射剂量、对比剂强化、图像噪声和心率变异性。结果显示双聚焦扫描法辐射剂量显著更低,而对比剂强化和图像噪声无显著差异,心率变异性≥20次/分的比例也更低。
要点
- 双聚焦扫描法较传统单次扫描显著降低辐射剂量(有效剂量5.3 vs 8.9 mSv)。
- 两种方法左右心室对比剂强化和图像噪声无显著差异。
- 双聚焦扫描法心率变异性≥20次/分的比例显著更低(3.1% vs 15.6%)。
诊断标准与关键数值
- 组1容积CT剂量指数、剂量长度乘积及有效剂量估计值均显著高于组2(分别为28.4±24.6 mGy vs 9.7±4.5 mGy、636.5±572.9 mGy cm vs 379.5±192.4 mGy cm、8.9±8.0 mSv vs 5.3±2.7 mSv、8.2±6.4 mSv vs 5.0±2.2 mSv;p值<0.019)。
- 两组右心室和左心室对比剂强化无显著差异(分别为470.2±152.4 HU vs 481.0±139.2 HU和428.6±97.8 HU vs 429.3±106.7 HU;p值>0.05)。
- 两组空气中测量的图像噪声无显著差异(5.6±1.9 HU vs 5.5±1.1 HU;p>0.05)。
- 组1心率变异性≥20次/分的比例显著高于组2(15.6%,5/32 vs 3.1%,2/64;p<0.040)。
临床应用与阅片要点
- 对于先天性心脏病患者需行ECG门控CT心室容积测量时,双聚焦扫描法可在保持对比剂强化和图像噪声相当的前提下降低辐射剂量。
- 双聚焦扫描法可能有助于减少心率变异性≥20次/分的发生。
局限性
- 原文未报告局限性
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE: To compare radiation dose, contrast enhancement, image noise and heart rate variability in electrocardiography (ECG)-gated computed tomography (CT) ventricular volumetry using a three-dimensional (3D) threshold-based segmentation between the conventional single scan and dual focused scan methods in patients with congenital heart disease.
METHODS: After matching for age, sex, heart rate during the CT examination, and tube voltage, 96 patients (age range, 7 - 36 years; male:female = 63:33) who underwent ECG-gated CT volumetry using a 3D threshold-based segmentation, were divided into 32 patients who underwent a conventional single scan (group 1) and 64 who underwent dual focused scans (group 2). CT radiation dose, contrast enhancement, image noise, and heart rate variability were compared between the two groups.
RESULTS: Volume CT dose index, dose-length product, and effective dose estimates, in group 1 were significantly higher than those in group 2 (28.4 ± 24.6 mGy vs. 9.7 ± 4.5 mGy, 636.5 ± 572.9 mGy cm vs. 379.5 ± 192.4 mGy cm, 8.9 ± 8.0 mSv vs. 5.3 ± 2.7 mSv, 8.2 ± 6.4 mSv vs. 5.0 ± 2.2 mSv, respectively; p values < 0.019). No significant differences in right and left ventricular contrast enhancement were found between the two groups (470.2 ± 152.4 HU vs. 481.0 ± 139.2 HU and 428.6 ± 97.8 HU vs. 429.3 ± 106.7 HU, respectively; p values > 0.05). Image noise measured in the air showed no significant differences between groups 1 and 2 (5.6 ± 1.9 HU vs. 5.5 ± 1.1 HU; p > 0.05). The proportion of heart rate variability ≥ 20 beats per minute in group 1 (15.6 %, 5/32) was significantly higher than that in group 2 (3.1 %, 2/64; p < 0.040).
CONCLUSION: Compared with the conventional single scan method, the dual focused scan method can provide a lower radiation dose with comparable contrast enhancement and image noise for ECG-gated CT ventricular volumetry using a 3D threshold-based segmentation in patients with congenital heart disease.