三维打印先天性心脏病模型用于心脏外科手术模拟:无经验心胸外科医师手术技能提升评估
研究用6月龄法洛四联症伴复杂肺动脉狭窄患者的术前心电门控CT扫描,以Stratasys Object500 Connex2打印机和Tango 27复合材料打印1:1心脏模型。6名心胸外科医师各完成3次模拟手术,第3次室间隔缺损与右室流出道补片应用时间较第1次显著缩短,10项手术操作评分从28.58±7.89分升至67.33±15.10分(p=0.008)。
要点
- 1:1三维打印法洛四联症模型可模拟室间隔缺损与右室流出道补片缝合操作。
- 6名医师第3次模拟手术的室间隔缺损补片时间中位数17.3分钟,低于第1次34.4分钟(p=0.03)。
- 10项操作总评分从第1次28.58±7.89分升至第3次67.33±15.10分(p=0.008)。
诊断标准与关键数值
- 手术熟练度由1名有经验的心胸外科医师按1–10分对10项手术操作分别评分,汇总10项得分进行比较。
- 6名医师第1次模拟手术室间隔缺损补片应用中位时间34.4分钟(范围32.5–43.5),第3次降至17.3分钟(范围16.2–29.5),p=0.03。
- 6名医师第1次模拟手术右室流出道补片应用中位时间21.4分钟(范围17.9–192.7),第3次降至13.6分钟(范围10.3–30.0),p=0.01。
- 6名医师室间隔缺损补片应用中位时间下降16.2分钟(范围13.6–17.7),右室流出道补片应用中位时间下降8.0分钟(范围1.8–170.3)。
- 10项操作总评分第1次模拟手术平均28.58±7.89分,第3次平均67.33±15.10分,p=0.008。
临床应用与阅片要点
- 作者结论认为,使用Tango 27复合材料三维打印法洛四联症模型进行3次模拟手术,可改善无经验心胸外科医师的手术熟练度与操作时间。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE: To evaluate the impact of surgical simulation training using a three-dimensional (3D)-printed model of tetralogy of Fallot (TOF) on surgical skill development.
MATERIALS AND METHODS: A life-size congenital heart disease model was printed using a Stratasys Object500 Connex2 printer from preoperative electrocardiography-gated CT scans of a 6-month-old patient with TOF with complex pulmonary stenosis. Eleven cardiothoracic surgeons independently evaluated the suitability of four 3D-printed models using composite Tango 27, 40, 50, and 60 in terms of palpation, resistance, extensibility, gap, cut-through ability, and reusability of. Among these, Tango 27 was selected as the final model. Six attendees (two junior cardiothoracic surgery residents, two senior residents, and two clinical fellows) independently performed simulation surgeries three times each. Surgical proficiency was evaluated by an experienced cardiothoracic surgeon on a 1-10 scale for each of the 10 surgical procedures. The times required for each surgical procedure were also measured.
RESULTS: In the simulation surgeries, six surgeons required a median of 34.4 (range 32.5-43.5) and 21.4 (17.9-192.7) minutes to apply the ventricular septal defect (VSD) and right ventricular outflow tract (RVOT) patches, respectively, on their first simulation surgery. These times had significantly reduced to 17.3 (16.2-29.5) and 13.6 (10.3-30.0) minutes, respectively, in the third simulation surgery (p = 0.03 and p = 0.01, respectively). The decreases in the median patch appliance time among the six surgeons were 16.2 (range 13.6-17.7) and 8.0 (1.8-170.3) minutes for the VSD and RVOT patches, respectively. Summing the scores for the 10 procedures showed that the attendees scored an average of 28.58 ± 7.89 points on the first simulation surgery and improved their average score to 67.33 ± 15.10 on the third simulation surgery (p = 0.008).
CONCLUSION: Inexperienced cardiothoracic surgeons improved their performance in terms of surgical proficiency and operation time during the experience of three simulation surgeries using a 3D-printed TOF model using Tango 27 composite.
引用
- Nam JG, Lee W, Jeong B, et al. Three-Dimensional Printing of Congenital Heart Disease Models for Cardiac Surgery Simulation: Evaluation of Surgical Skill Improvement among Inexperienced Cardiothoracic Surgeons. Korean J Radiol. 2020. PMID: 33543844. doi:10.3348/kjr.2020.0682
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。