基于深度学习的主动脉瓣钙化自动检测与定量算法开发

Development of a deep learning-based algorithm for the automatic detection and quantification of aortic valve calcium.
PubMed 文献 · Eur J Radiol · 2021-02-06

该研究开发了基于深度学习的算法,用于在非增强心电门控心脏CT上自动分割和定量主动脉瓣钙化体积及Agatston评分。回顾性纳入2010年3月至2017年8月单中心589例CT检查,以手动测量为参考标准,DL测量体积和Agatston评分在重度AVC分类中的诊断性能优于放射科医师视觉分级。

要点

  • DL算法自动分割主动脉瓣钙化并计算体积和Agatston评分,Dice系数0.807。
  • DL测量体积分类AVC的AUC 0.964,优于放射科医师的AUC 0.762-0.923。
  • DL测量Agatston评分分类AVC的AUC 0.933,优于放射科医师的AUC 0.791-0.903。

诊断标准与关键数值

  • DL算法分割AVC的Dice系数为0.807。
  • 在测试集中,以手动测量AVC体积为参考标准,DL测量体积分类AVC的准确度97.0%,AUC 0.964(95%CI 0.923-1)。
  • 以手动测量AVC体积为参考标准,放射科医师分类AVC的准确度69.7%-91.9%,AUC 0.762-0.923。
  • 以手动测量AVC Agatston评分为参考标准,DL测量Agatston评分分类AVC的准确度92.9%,AUC 0.933(95%CI 0.885-0.981)。
  • 以手动测量AVC Agatston评分为参考标准,放射科医师分类AVC的准确度77.8%-89.9%,AUC 0.791-0.903。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: We aimed to develop a deep learning (DL)-based algorithm for automated quantification of aortic valve calcium (AVC) from non-enhanced electrocardiogram-gated cardiac CT scans and compare performance of DL-measured AVC volume and Agatston score with those of visual gradings by radiologist readers for classification of AVC severity.

METHOD: A total of 589 CT examinations performed at a single center between March 2010 and August 2017 were retrospectively included. The DL algorithm was designed to segment AVC and to quantify AVC volume, and Agatston score was calculated using attenuation values. Manually measured AVC volume and Agatston score were used as ground truth. To validate AVC segmentation performance, the Dice coefficient was calculated. For observer performance testing, four radiologists determined AVC grade in two reading rounds. The diagnostic performance of DL-measured AVC volume and Agaston score for classifying severe AVC was compared with that of each reader's assessment.

RESULTS: After applying the DL algorithm, the Dice coefficient score was 0.807. In patients with AVC, accuracy of DL-measured AVC volume for AVC grading was 97.0 % with area under the curve (AUC) of 0.964 (95 % confidence interval [CI] 0.923-1) in the test set, which was better than the radiologist readers (accuracy 69.7 %-91.9 %, AUC 0.762-0.923) with manually measured AVC volume as ground truth. When manually measured AVC Agatston score was used as ground truth, accuracy of DL-measured AVC Agatston score for AVC grading was 92.9 % with AUC of 0.933 (95 % CI 0.885-0.981) in the test set, which was also better than the radiologist readers (accuracy 77.8-89.9 %, AUC 0.791-0.903).

CONCLUSIONS: DL-based automated AVC quantification may be comparable with manual measurements. The diagnostic performance of the DL-measured AVC volume and Agatston score for classification of severe AVC outperforms radiologist readers.

来源:Eur J Radiol,查看原文。版权归原作者所有。