冠状动脉CT血管成像中位置自适应阈值用于冠状动脉管腔分割:一项概念验证研究

Coronary Artery Lumen Segmentation Using Location-Adaptive Threshold in Coronary Computed Tomographic Angiography: A Proof-of-Concept.
PubMed 文献 · Korean J Radiol · 2020-12-21

本研究对15例患者22个目标冠状动脉节段,比较位置自适应阈值法(LATM,校正扫描间和扫描内衰减变异性)与扫描自适应阈值法(SATM,仅校正扫描间变异性)测量的管腔参数,以血管内超声(IVUS)为参考标准。SATM测量的管腔体积显著小于IVUS(平均差14.6 mm³;95%CI 4.9-24.3 mm³),LATM与IVUS无显著差异(平均差-0.7 mm³;95%CI -9.1-7.7 mm³)。结论认为SATM低估管腔参数,LATM可能克服此问题。

要点

  • SATM测量的管腔体积显著小于IVUS参考标准,平均差14.6 mm³(95%CI 4.9-24.3 mm³)。
  • LATM测量的管腔体积与IVUS无显著差异,平均差-0.7 mm³(95%CI -9.1-7.7 mm³)。
  • 小管腔面积组中SATM测值显著小于LATM,平均差1.07 mm²(95%CI 0.89-1.25 mm²)。

诊断标准与关键数值

  • 以IVUS-derived reference standard为参考,SATM测量的管腔体积显著小于IVUS,平均差14.6 mm³(95%CI 4.9-24.3 mm³)。
  • LATM测量的管腔体积与IVUS无显著差异,平均差-0.7 mm³(95%CI -9.1-7.7 mm³)。
  • 小管腔面积组中SATM测量的管腔面积显著小于LATM,平均差1.07 mm²(95%CI 0.89-1.25 mm²);大管腔面积组中两者无显著差异,平均差-0.07 mm²(95%CI -0.22-0.08 mm²)。
  • 小管腔组Bland-Altman图中,IVUS与LATM的平均差为0.46 mm²(95%CI 0.27-0.65 mm²),低于IVUS与SATM的平均差1.53 mm²(95%CI 1.27-1.79 mm²)。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: To compare the lumen parameters measured by the location-adaptive threshold method (LATM), in which the inter- and intra-scan attenuation variabilities of coronary computed tomographic angiography (CCTA) were corrected, and the scan-adaptive threshold method (SATM), in which only the inter-scan variability was corrected, with the reference standard measurement by intravascular ultrasonography (IVUS).

MATERIALS AND METHODS: The Hounsfield unit (HU) values of whole voxels and the centerline in each of the cross-sections of the 22 target coronary artery segments were obtained from 15 patients between March 2009 and June 2010, in addition to the corresponding voxel size. Lumen volume was calculated mathematically as the voxel volume multiplied by the number of voxels with HU within a given range, defined as the lumen for each method, and compared with the IVUS-derived reference standard. Subgroup analysis of the lumen area was performed to investigate the effect of lumen size on the studied methods. Bland-Altman plots were used to evaluate the agreement between the measurements.

RESULTS: Lumen volumes measured by SATM was significantly smaller than that measured by IVUS (mean difference, 14.6 mm³; 95% confidence interval [CI], 4.9-24.3 mm³); the lumen volumes measured by LATM and IVUS were not significantly different (mean difference, -0.7 mm³; 95% CI, -9.1-7.7 mm³). The lumen area measured by SATM was significantly smaller than that measured by LATM in the smaller lumen area group (mean of difference, 1.07 mm²; 95% CI, 0.89-1.25 mm²) but not in the larger lumen area group (mean of difference, -0.07 mm²; 95% CI, -0.22-0.08 mm²). In the smaller lumen group, the mean difference was lower in the Bland-Altman plot of IVUS and LATM (0.46 mm²; 95% CI, 0.27-0.65 mm²) than in that of IVUS and SATM (1.53 mm²; 95% CI, 1.27-1.79 mm²).

CONCLUSION: SATM underestimated the lumen parameters for computed lumen segmentation in CCTA, and this may be overcome by using LATM.