文献速递胸部CT

使用市售深度学习算法测量CT上表现为亚实性病变的肺癌实性部分:与放射科医师及病理浸润成分大小的比较

Use of a Commercially Available Deep Learning Algorithm to Measure the Solid Portions of Lung Cancer Manifesting as Subsolid Lesions at CT: Comparisons with Radiologists and Invasive Component Size at Pathologic Examination.
PubMed 文献 · Radiology · 2021-02-02

回顾性纳入2018年1月至12月CT上表现为亚实性病变且经手术证实的肺腺癌448例,比较5名放射科医师手动测量、深度学习算法自动测量与病理浸润成分大小。算法与各医师测量一致性很好(ICC 0.82-0.89),与病理浸润成分一致性良好(ICC 0.67),但算法和医师均低估病理浸润成分大小。

要点

  • 深度学习算法自动测量亚实性肺癌实性部分与放射科医师手动测量一致性很好(ICC 0.82-0.89)。
  • 算法与病理浸润成分大小一致性良好(ICC 0.67),但平均低估6.0 mm。
  • 算法与各医师测量的一致性界限最宽达-15.7至8.3 mm,宽于医师两两比较。

诊断标准与关键数值

  • 各放射科医师与深度学习算法测量一致性很好,ICC范围0.82-0.89。
  • 以算法替换一名医师后ICC为0.87-0.90,5名医师之间ICC为0.90。
  • 算法与各医师平均差异范围-3.7至1.5 mm。
  • 算法与各医师最宽95%一致性界限为-15.7至8.3 mm,宽于医师两两比较的-7.7至13.0 mm。
  • 算法与病理浸润成分大小一致性良好,ICC为0.67;算法平均差异-6.0 mm,医师平均差异-7.5至-2.3 mm,均低估浸润成分大小。

临床应用与阅片要点

  • 市售深度学习算法可自动分割并测量亚实性肺癌实性部分的最大轴位径线,与放射科医师手动测量一致性很好。
  • 算法测量与病理浸润成分大小一致性良好但平均低估6.0 mm,阅片和报告时需注意该低估倾向。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

Background The solid portion size of lung cancer lesions manifesting as subsolid lesions is key in their management, but the automatic measurement of such lesions by means of a deep learning (DL) algorithm needs evaluation. Purpose To evaluate the performance of a commercially available DL algorithm for automatic measurement of the solid portion of surgically proven lung adenocarcinomas manifesting as subsolid lesions. Materials and Methods Surgically proven lung adenocarcinomas manifesting as subsolid lesions on CT images between January 2018 and December 2018 were retrospectively included. Five radiologists independently measured the maximal axial diameter of the solid portion of lesions. The DL algorithm automatically segmented and measured the maximal axial diameter of the solid portion. Reader measurements, software measurements, and invasive component size at pathologic examination were compared by using intraclass correlation coefficient (ICC) and Bland-Altman plots. Results A total of 448 patients (mean age, 63 years ± 10 [standard deviation]; 264 women) with 448 lesions were evaluated (invasive component size, 3-65 mm). The measurement agreements between each radiologist and the DL algorithm were very good (ICC range, 0.82-0.89). When a radiologist was replaced with the DL algorithm, the ICCs ranged from 0.87 to 0.90, with an ICC of 0.90 among five radiologists. The mean difference between the DL algorithm and each radiologist ranged from -3.7 to 1.5 mm. The widest 95% limit of agreement between the DL algorithm and each radiologist (-15.7 to 8.3 mm) was wider than pairwise comparisons of radiologists (-7.7 to 13.0 mm). The agreement between the DL algorithm and invasive component size at pathologic evaluation was good, with an ICC of 0.67. Measurements by the DL algorithm (mean difference, -6.0 mm) and radiologists (mean difference, -7.5 to -2.3 mm) both underestimated invasive component size. Conclusion Automatic measurements of solid portions of lung cancer manifesting as subsolid lesions by the deep learning algorithm were comparable with manual measurements and showed good agreement with invasive component size at pathologic evaluation. © RSNA, 2021 Online supplemental material is available for this article.

来源:Radiology,查看原文。版权归原作者所有。

引用

  1. Ahn Y, Lee SM, Noh HN, et al. Use of a Commercially Available Deep Learning Algorithm to Measure the Solid Portions of Lung Cancer Manifesting as Subsolid Lesions at CT: Comparisons with Radiologists and Invasive Component Size at Pathologic Examination. Radiology. 2021. PMID: 33529136. doi:10.1148/radiol.2021202803

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。