单源双能量全身CT血管成像40 keV重建联合50%碘剂量减量的优势与不足

Advantages and disadvantages of single-source dual-energy whole-body CT angiography with 50% reduced iodine dose at 40 keV reconstruction.
PubMed 文献 · Br J Radiol · 2021-02-22

65例患者行全身CTA,31例接受120 kVp单能量CTA(标准碘剂量600 mgI/kg),34例接受40 keV双能量CTA(50%减碘剂量300 mgI/kg),比较血管CT值、背景噪声、SNR及动脉显示。双能量组血管CT值和噪声显著更高,SNR以双能量80%组最高、单能量组次之、双能量40%组最低;除盆腔内动脉显示双能量组显著较差外,其余动脉显示相仿;双能量方案胸部与腹部CTDIvol显著更高,盆腔CTDIvol两组差异无统计学意义。

要点

  • 40 keV双能量CTA在50%减碘(300 mgI/kg)下血管CT值和SNR高于单能量CTA,多数动脉显示相仿。
  • 盆腔内动脉显示在双能量组显著差于单能量组,阅片时需注意该区域血管评估受限。
  • 双能量方案胸部与腹部CTDIvol显著高于单能量方案,盆腔CTDIvol两组无显著差异。

关键影像表现/征象

  • 双能量组血管CT值和背景噪声显著高于单能量组(p < 0.001)。
  • SNR由高到低依次为双能量80%组、单能量组、双能量40%组(p < 0.001)。
  • 几乎所有动脉的动脉显示相仿,但盆腔内动脉显示双能量组显著差于单能量组(p < 0.0001-0.017)。

临床应用与阅片要点

  • 双能量40 keV重建可在50%减碘剂量下用于全身CTA,但盆腔内动脉显示较差,报告中对该区域血管评估需谨慎。
  • 双能量方案胸部(p < 0.0001)和腹部(p = 0.0031)CTDIvol显著高于单能量方案,盆腔CTDIvol两组差异无统计学意义(p = 0.055)。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: To assess the feasibility of whole-body dual-energy computed tomographic angiography (DECTA) at 40 keV with 50% reduced iodine dose protocol.

METHODS: Whole-body CTA was performed in 65 patients; 31 of these patients underwent 120 kVp single-energy computed tomographic angiography (SECTA) with standard iodine dose (600 mgI/kg) and 34 with 40 keV DECTA with 50% reduced iodine dose (300 mgI/kg). SECTA data were reconstructed with adaptive statistical iterative reconstruction of 40% (SECTA group), and DECTA data were reconstructed with adaptive statistical iterative reconstruction of 40% (DECTA-40% group) and 80% (DECTA-80% group). CT numbers of the thoracic and abdominal aorta, iliac artery, background noise, signal-to-noise ratio (SNR), and arterial depiction were compared among the three groups. The CT dose index volumes (CTDIvol) for the thorax, abdomen, and pelvis were compared between SECTA and DECTA protocols.

RESULTS: The vascular CT numbers and background noise were found to be significantly higher in DECTA groups than in the SECTA group (p < 0.001). SNR was significantly higher in the order corresponding to DECTA-80%, SECTA, and DECTA-40% (p < 0.001). The arterial depiction was comparable in almost all arteries; however, intrapelvic arterial depiction was significantly worse in DECTA groups than in the SECTA group (p < 0.0001-0.017). Unlike the pelvic region (p = 0.055), CTDIvol for the thorax (p < 0.0001) and abdomen (p = 0.0031) were significantly higher in the DECTA protocol than in the SECTA protocol.

CONCLUSION: DECTA at 40 keV with 50% reduced iodine dose provided higher vascular CT numbers and SNR than SECTA, and almost comparable arterial depiction, but had a degraded intrapelvic arterial depiction and required a larger radiation dose.

ADVANCES IN KNOWLEDGE: DECTA enables 50% reduction of iodine dose while maintaining image quality, arterial depiction in almost all arteries, vascular CT numbers, and SNR; however, it does not allow clear visualization of intrapelvic arteries, requiring a slightly larger radiation dose compared with SECTA with standard iodine dose.

来源:Br J Radiol,查看原文。版权归原作者所有。