吸气/呼气相氙增强区域探测器CT:对接受手术的非小细胞肺癌患者肺通气变化的定量评估能力
本研究纳入40例连续接受手术的非小细胞肺癌患者,术前术后行吸气/呼气相氙增强区域探测器CT及肺功能检查,逐像素生成通气指数图。结果显示通气指数变化与肺功能参数变化相关,逐步回归分析表明ΔVR和ΔWI显著影响FEV1/FVC%、%FEV1和%VC的变化。结论认为该技术有潜力显示手术前后通气状态与肺功能的相关性。
要点
- 氙增强区域探测器CT可逐像素生成通气指数图,定量评估区域性通气。
- ΔVR与%FEV1变化的相关系数r=0.76,为各通气指数中相关性较高者。
- 逐步回归显示ΔVR和ΔWI显著影响术后肺功能参数变化。
诊断标准与关键数值
- FEV1/FVC%变化与ΔWI显著相关(r=0.39,p=0.01),与ΔVR显著相关(r=0.68,p=0.001)。
- %FEV1变化与ΔWI显著相关(r=0.56,p=0.0001),与ΔVR显著相关(r=0.76,p<0.0001)。
- %VC变化与ΔWI显著相关(r=0.65,p<0.0001),与ΔVR显著相关(r=0.67,p<0.0001)。
- 逐步回归分析显示FEV1/FVC%变化(r²=0.56,p<0.0001)显著受ΔVR(p<0.0001)和ΔWI(p=0.006)影响。
- 逐步回归分析显示%FEV1变化(r²=0.68,p<0.0001)显著受ΔVR(p<0.0001)和ΔWI(p=0.0001)影响;%VC变化(r²=0.63,p<0.0001)显著受ΔVR(p<0.0001)和ΔWI(p=0.0001)影响。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: To evaluate the capability of inspiratory/expiratory Xe-enhanced ADCT for assessment of changes in pulmonary function and regional ventilation of surgically treated NSCLC patients.
METHOD AND MATERIALS: Forty consecutive surgically treated NSCLC patients underwent pre- and postoperative inspiratory/expiratory Xe-enhanced ADCT and pulmonary function tests. For each patient, pre- and post-operative data were analyzed and pre- and post-operative wash-in (WI) and wash-out (WO) indexes and ventilation ratio (VR=[WI-WO]/WI) maps generated by means of pixel-by-pixel analyses. Differences between pre- and postoperative WI (ΔWI), WO (ΔWO) and VR (ΔVR) were also determined. To determine the relationship between all ventilation index changes and pulmonary functional loss, Pearson's correlation was used to correlate each ventilation index change with the corresponding pulmonary functional parameter change. In addition, stepwise regression analysis was performed for all ventilation index changes and each corresponding pulmonary functional parameter change.
RESULTS: FEV1/FVC% change showed fair or good and significant correlations with ΔWI (r = 0.39, p = 0.01) and ΔVR (r = 0.68, p = 0.001), %FEV1 change good or moderate and significant correlations with ΔWI (r = 0.56, p = 0.0001) and ΔVR (r = 0.76, p < 0.0001), and %VC change moderate yet significant correlation with ΔWI (r = 0.65, p < 0.0001) and ΔVR (r = 0.67, p < 0.0001). Stepwise regression analysis demonstrated that FEV1/FVC% change (r2 = 0.56, p < 0.0001) significantly affected two factors, ΔVR (p < 0.0001) and ΔWI (p = 0.006), as did %FEV1 change (r2 = 0.68, p < 0.0001) [ΔVR (p < 0.0001) and ΔWI (p = 0.0001)], and %VC change (r2 = 0.63, p < 0.0001) [ΔVR (p < 0.0001) and ΔWI (p = 0.0001)].
CONCLUSION: Inspiratory/expiratory Xe-enhanced ADCT has the potential to demonstrate that pre- and postoperative ventilation status of surgically treated NSCLC patients correlates with pulmonary function.
引用
- Ohno Y, Fujisawa Y, Yoshikawa T, et al. Inspiratory/expiratory xenon-enhanced area-detector CT: Capability for quantitative assessment of lung ventilation changes in surgically treated non-small cell lung cancer patients. Eur J Radiol. 2021. PMID: 33548852. doi:10.1016/j.ejrad.2021.109574
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。