CT卷积核对外不同肺部疾病及组织类型影像组学特征稳健性的影响

Impact of CT convolution kernel on robustness of radiomic features for different lung diseases and tissue types.
PubMed 文献 · Br J Radiol · 2021-02-05

回顾性收集23例非小细胞肺癌、10例恶性胸膜间皮瘤和12例系统性硬化相关间质性肺病患者治疗前平扫CT,分别用平滑与锐利卷积核重建,分析1386个影像组学特征的稳健性。结果显示重建方法对特征稳定性影响很大,最多仅26%的特征稳定,淋巴结影像组学稳定性最差(<10%),肺组织最高(26%),稳健性结果不能跨组织类型转移,受组织类型影响大于疾病类型。

要点

  • CT重建卷积核显著影响影像组学特征稳定性,最多仅26%的1386个特征稳定。
  • 强度特征最稳定,其次为纹理和小波特征;淋巴结影像组学稳定性最差(<10%)。
  • 稳健性结果不能跨组织类型转移,但不同肺部疾病间肺组织稳定特征重叠超过50%。
英文原文(摘要)· 点击展开

OBJECTIVES: In this study, we aimed to assess the impact of different CT reconstruction kernels on the stability of radiomic features and the transferability between different diseases and tissue types. Three lung diseases were evaluated, i.e. non-small cell lung cancer (NSCLC), malignant pleural mesothelioma (MPM) and interstitial lung disease related to systemic sclerosis (SSc-ILD) as well as four different tissue types, i.e. primary tumor, largest involved lymph node ipsilateral and contralateral lung.

METHODS: Pre-treatment non-contrast enhanced CT scans from 23 NSCLC, 10 MPM and 12 SSc-ILD patients were collected retrospectively. For each patient, CT scans were reconstructed using smooth and sharp kernel in filtered back projection. The regions of interest (ROIs) were contoured on the smooth kernel-based CT and transferred to the sharp kernel-based CT. The voxels were resized to the largest voxel dimension of each cohort. In total, 1386 features were analyzed. Feature stability was assessed using the intraclass correlation coefficient. Features above the stability threshold >0.9 were considered stable.

RESULTS: We observed a strong impact of the reconstruction method on stability of the features (at maximum 26% of the 1386 features were stable). Intensity features were the most stable followed by texture and wavelet features. The wavelet features showed a positive correlation between percentage of stable features and size of the ROI (R2 = 0.79, p = 0.005). Lymph node radiomics showed poorest stability (<10%) and lung radiomics the largest stability (26%). Robustness analysis done on the contralateral lung could to a large extent be transferred to the ipsilateral lung, and the overlap of stable lung features between different lung diseases was more than 50%. However, results of robustness studies cannot be transferred between tissue types, which was investigated in NSCLC and MPM patients; the overlap of stable features for lymph node and lung, as well as for primary tumor and lymph node was very small in both disease types.

CONCLUSION: The robustness of radiomic features is strongly affected by different reconstruction kernels. The effect is largely influenced by the tissue type and less by the disease type.

ADVANCES IN KNOWLEDGE: The study presents to our knowledge the most complete analysis on the impact of convolution kernel on the robustness of CT-based radiomics for four relevant tissue types in three different lung diseases. .