文献速递胸部CT

胸部CT亚实性结节的计算机辅助检测:基于深度学习的CT层厚缩减可提升性能

Computer-aided Detection of Subsolid Nodules at Chest CT: Improved Performance with Deep Learning-based CT Section Thickness Reduction.
PubMed 文献 · Radiology · 2021-02-09

本研究回顾性评估1、3、5毫米层厚对计算机辅助检测(CAD)检出亚实性结节的影响,并分析超分辨率算法将3、5毫米图像转换为1毫米层厚后的效果。结果显示1毫米层厚CAD性能优于3、5毫米,非实性结节差异更明显;超分辨率算法可提升3、5毫米层厚的CAD敏感度。

要点

  • 1毫米层厚CT上CAD检出亚实性结节的性能优于3毫米和5毫米层厚。
  • 层厚对非实性结节CAD性能影响显著,对部分实性结节无显著差异。
  • 超分辨率算法可提升3毫米和5毫米层厚CT上CAD的敏感度。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

Background Studies on the optimal CT section thickness for detecting subsolid nodules (SSNs) with computer-aided detection (CAD) are lacking. Purpose To assess the effect of CT section thickness on CAD performance in the detection of SSNs and to investigate whether deep learning-based super-resolution algorithms for reducing CT section thickness can improve performance. Materials and Methods CT images obtained with 1-, 3-, and 5-mm-thick sections were obtained in patients who underwent surgery between March 2018 and December 2018. Patients with resected synchronous SSNs and those without SSNs (negative controls) were retrospectively evaluated. The SSNs, which ranged from 6 to 30 mm, were labeled ground-truth lesions. A deep learning-based CAD system was applied to SSN detection on CT images of each section thickness and those converted from 3- and 5-mm section thickness into 1-mm section thickness by using the super-resolution algorithm. The CAD performance on each section thickness was evaluated and compared by using the jackknife alternative free response receiver operating characteristic figure of merit. Results A total of 308 patients (mean age ± standard deviation, 62 years ± 10; 183 women) with 424 SSNs (310 part-solid and 114 nonsolid nodules) and 182 patients without SSNs (mean age, 65 years ± 10; 97 men) were evaluated. The figures of merit differed across the three section thicknesses (0.92, 0.90, and 0.89 for 1, 3, and 5 mm, respectively; P = .04) and between 1- and 5-mm sections (P = .04). The figures of merit varied for nonsolid nodules (0.78, 0.72, and 0.66 for 1, 3, and 5 mm, respectively; P < .001) but not for part-solid nodules (range, 0.93-0.94; P = .76). The super-resolution algorithm improved CAD sensitivity on 3- and 5-mm-thick sections (P = .02 for 3 mm, P < .001 for 5 mm). Conclusion Computer-aided detection (CAD) of subsolid nodules performed better at 1-mm section thickness CT than at 3- and 5-mm section thickness CT, particularly with nonsolid nodules. Application of a super-resolution algorithm improved the sensitivity of CAD at 3- and 5-mm section thickness CT. © RSNA, 2021 Online supplemental material is available for this article. See also the editorial by Goo in this issue.

来源:Radiology,查看原文。版权归原作者所有。

引用

  1. Park S, Lee SM, Kim W, et al. Computer-aided Detection of Subsolid Nodules at Chest CT: Improved Performance with Deep Learning-based CT Section Thickness Reduction. Radiology. 2021. PMID: 33560190. doi:10.1148/radiol.2021203387

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。