文献速递胸部PETCT

基于数字化低剂量18F-FDG PET区域代谢活性分布检测肺癌的初步研究

A pilot study on lung cancer detection based on regional metabolic activity distribution in digital low-dose 18F-FDG PET.
PubMed 文献 · Br J Radiol · 2021-02-02

回顾性队列分析83例接受18F-FDG PET/CT的患者(34例组织学证实肺癌,49例无肺病),从标准PET及仅用15秒和5秒原始数据重建的10%和3.3%低剂量PET中提取肺段SUV参数,多变量模型诊断肺癌的AUC在全剂量PET为0.97、PET10%为0.85,PET10%重建的敏感度仍高达80%。

要点

  • SUVstd是肺癌检测最重要的判别因素。
  • 全剂量PET多变量模型AUC为0.97,PET10%重建AUC为0.85。
  • PET10%重建检测肺癌的敏感度仍达80%。

核心结论

  • 本初步研究表明,基于肺段水平的低剂量PET重建定量参数可自动检测肺癌,且敏感度高。
  • 低剂量PET参数自动评估可能有助于肺癌的早期检测。

研究设计与样本

  • 回顾性队列分析,纳入83例转诊行18F-FDG PET/CT的患者,其中34例组织学证实肺癌、49例无肺病。
  • 除临床标准PET图像(PET100%)外,利用150秒列表模式原始数据中仅15秒和5秒数据重建两个低剂量PET,分别对应原始18F-FDG活性的10%和3.3%。
  • 每侧肺分为三个肺段,每段分类为正常或含肺癌,从每个肺段PET提取SUVmean、SUVhot5、SUVmedian、SUVstd和SUVtotal。
  • 采用多变量线性回归模型并进行交叉验证,以受试者工作特征分析检验肺癌检测准确性,用T统计量计算各参数权重。

诊断标准与关键数值

  • T统计量显示SUVstd是肺癌检测最重要的判别因素。
  • 多变量模型诊断肺癌的AUC:全剂量PET为0.97,PET10%重建为0.85。
  • PET10%重建检测肺癌的敏感度仍高达80%。

临床应用与阅片要点

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: To investigate the potential of automatic lung cancer detection on submillisievert dose 18F-fludeoxyglucose (18F-FDG) scans using different positron emission tomography (PET) parameters, as a primary step towards a potential new indication for 18F-FDG PET in lung cancer screening.

METHODS: We performed a retrospective cohort analysis with 83 patients referred for 18F-FDG PET/CT, including of 34 patients with histology-proven lung cancer and 49 patients without lung disease. Aside clinical standard PET images (PET100%) two additional low-dose PET reconstructions were generated, using only 15 s and 5 s of the 150 s list mode raw data of the full-dose PET, corresponding to 10% and 3.3% of the original 18F-FDG activity. The lungs were subdivided into three segments on each side, and each segment was classified as normal or containing cancer. The following standardized uptake values (SUVs) were extracted from PET per lung segment: SUVmean, SUVhot5, SUVmedian, SUVstd and SUVtotal. A multivariate linear regression model was used and cross-validated. The accuracy for lung cancer detection was tested with receiver operating characteristics analysis and T-statistics was used to calculate the weight of each parameter.

RESULTS: The T-statistics showed that SUVstd was the most important discriminative factor for lung cancer detection. The multivariate model achieved an area under the curve of 0.97 for full-dose PET, 0.85 for PET10% with PET3.3% reconstructions resulting in a still high sensitivity the PET10% reconstruction of 80%.

CONCLUSION: This pilot study indicates that segment-based, quantitative PET parameters of low-dose PET reconstructions could be used to automatically detect lung cancer with high sensitivity.

ADVANCES IN KNOWLEDGE: Automated assessment of PET parameters in low-dose PET may aid for an early detection of lung cancer.

来源:Br J Radiol,查看原文。版权归原作者所有。

引用

  1. Messerli M, Muehlematter UJ, Fassbind S, et al. A pilot study on lung cancer detection based on regional metabolic activity distribution in digital low-dose 18F-FDG PET. Br J Radiol. 2021. PMID: 33529052. doi:10.1259/bjr.20200244

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。