文献速递头颈神经CT

三维咽鼓管模型的形态学测量及其对咽鼓管功能障碍的诊断价值:一项横断面观察性研究

Morphologic measurements of 3D Eustachian tube model and their diagnostic value regarding Eustachian tube dysfunction - A cross-sectional observational study.
PubMed 文献 · Eur J Radiol · 2021-01-23

前瞻性横断面观察性研究纳入40例单侧咽鼓管功能障碍患者,以咽鼓管评分-7和咽鼓管功能障碍问卷-7为临床参考标准,在Valsalva动作下采集颞骨CT并构建三维模型测量7项形态学参数。结果显示健康侧咽鼓管全长及骨段的可视化长度显著高于病变侧,咽鼓管评分-7与鼓室口横截面大小及可视化长度显著相关;作者认为鼓室口横截面大小可能是提示阻塞性咽鼓管的特异性影像特征,但三维形态学测量不足以提供功能信息。

要点

  • 健康侧咽鼓管全长可视化长度显著高于病变侧(p=0.034)。
  • 健康侧咽鼓管骨段可视化长度显著高于病变侧(p=0.029)。
  • 咽鼓管评分-7与鼓室口横截面大小显著相关(rP=0.361;p=0.022)。

核心结论

  • 鼓室口横截面大小可能是提示阻塞性咽鼓管的特异性影像特征,但三维形态学测量不足以提供咽鼓管功能的有用数据。

研究设计与样本

  • 前瞻性横断面观察性研究,纳入40例单侧咽鼓管功能障碍患者。
  • 临床诊断以咽鼓管评分-7和咽鼓管功能障碍问卷-7验证。
  • 在Valsalva动作下采集颞骨CT以改善含气咽鼓管管腔的可视化。
  • 在曲面平面重建上勾画咽鼓管并构建三维模型,每侧咽鼓管测量7项形态学参数。

关键影像表现/征象

  • 健康侧咽鼓管全长可视化长度显著高于病变侧(p=0.034)。
  • 健康侧咽鼓管骨段可视化长度显著高于病变侧(p=0.029)。

诊断标准与关键数值

  • 咽鼓管评分-7与鼓室口横截面大小显著相关(rP=0.361;p=0.022)。
  • 咽鼓管评分-7与咽鼓管全长可视化长度显著相关(rP=0.436;p=0.005)。
  • 咽鼓管评分-7与咽鼓管骨段可视化长度显著相关(rS=0.598;p<0.0001)。

临床应用与阅片要点

  • 作者认为鼓室口横截面大小可能是提示阻塞性咽鼓管的特异性影像特征。
  • 作者认为三维形态学测量不足以提供咽鼓管功能的有用数据。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: To investigate the diagnostic value of three-dimensional morphologic measurements of the Eustachian tube on computed tomography in Eustachian tube dysfunction.

METHOD: This prospective cross-sectional observational study includes forty patients with unilateral Eustachian tube dysfunction. The clinical diagnosis is verified using the Eustachian tube score - 7 and the Eustachian tube dysfunction questionnaire - 7. Computed tomography scans of the temporal bone are acquired while performing a Valsalva manoeuvre to improve the visualization of the air-filled Eustachian tube lumen. The Eustachian tubes are delineated on curved planar reconstructions, and three-dimensional models are constructed. Seven morphological parameters are measured for each Eustachian tube: the cross-sectional size of the tympanic and pharyngeal orifice; the visualization length; the inclination angles, and the curvature angles. Morphological measurements and Eustachian tube scores are correlated.

RESULTS: The mean value of the visualization length of the complete Eustachian tube and in its bony segment is significantly higher in healthy sides than in pathological sides (p = 0.034 and p = 0.029, respectively). There is a significant correlation between the Eustachian tube score - 7 and the cross-sectional size of the tympanic orifice (rP = 0.361; p = 0.022). The Eustachian tube score - 7 correlates significantly with the visualization length of complete Eustachian tube (rP = 0.436; p = 0.005) and its bony segment (rS = 0.598; p < 0.0001), respectively.

CONCLUSIONS: The cross-sectional size of the tympanic orifice may be a specific imaging feature indicating the obstructive Eustachian tube. However, 3D morphologic measurements of the Eustachian tube are insufficient to yield useful data about its function.

来源:Eur J Radiol,查看原文。版权归原作者所有。

引用

  1. Kourtidis S, Bier G, Preyer S, et al. Morphologic measurements of 3D Eustachian tube model and their diagnostic value regarding Eustachian tube dysfunction - A cross-sectional observational study. Eur J Radiol. 2021. PMID: 33517248. doi:10.1016/j.ejrad.2021.109563

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。