脊柱顺应性曲线:评估自发性颅内低压患者疑诊脑脊液静脉瘘的CT脊髓造影新工具的初步经验
本研究在疑诊脑脊液静脉瘘患者行动态CT脊髓造影时,通过鞘内注射生理盐水并记录脑脊液压力变化,绘制颅脊空间顺应性曲线。22例患者共34次CT脊髓造影中,8例(36.4%)确诊脑脊液静脉瘘;确诊者开放压力顺应性和总体顺应性均高于未确诊者(2.6 vs 1.8 mL/cm H2O,P<.01),压力容积指数无差异。作者认为该曲线可提供压力-容积动力学信息,可能作为诊断工具。
要点
- 确诊脑脊液静脉瘘患者开放压力顺应性和总体顺应性高于未确诊者。
- 压力容积指数在确诊与未确诊脑脊液静脉瘘患者间无显著差异。
- 生理盐水团注耐受良好,34次检查中仅2次(5.8%)出现短暂头痛。
局限性
- 原文标题及结论均表述为初步经验与初步分析。
- 作者在结论中提出该曲线可能作为诊断工具,尚需进一步研究。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
BACKGROUND AND PURPOSE: Craniospinal space compliance reflects the distensibility of the spinal and intracranial CSF spaces as a system. Craniospinal space compliance has been studied in intracranial pathologies, but data are limited in assessing it in spinal CSF leak. This study describes a method to estimate craniospinal space compliance using saline infusion during CT myelography and explores the use of craniospinal space compliance and pressure-volume curves in patients with suspected cerebrospinal-venous fistula.
MATERIALS AND METHODS: Patients with suspected cerebrospinal-venous fistula underwent dynamic CT myelography. During the procedure, 1- to 5-mL boluses of saline were infused, and incremental changes in CSF pressure were recorded. These data were used to plot craniospinal space compliance curves. We calculated 3 quantitative craniospinal space compliance parameters: overall compliance, compliance at opening pressure, and the pressure volume index. These variables were compared between patients with confirmed cerebrospinal-venous fistula and those with no confirmed source of CSF leak.
RESULTS: Thirty-four CT myelograms in 22 patients were analyzed. Eight of 22 (36.4%) patients had confirmed cerebrospinal-venous fistulas. Bolus infusion was well-tolerated with no complications and transient headache in 2/34 (5.8%). Patients with confirmed cerebrospinal-venous fistulas had higher compliance at opening pressure and overall compliance (2.6 versus 1.8 mL/cm H20, P < .01). There was no difference in the pressure volume index (77.5 versus 54.3 mL, P = .13) between groups.
CONCLUSIONS: A method of deriving craniospinal space compliance curves using saline intrathecal infusion is described. Preliminary analysis of craniospinal space compliance curves provides qualitative and quantitative information about pressure-volume dynamics and may serve as a diagnostic tool in patients with known or suspected cerebrospinal-venous fistulas.
引用
- Caton MT, Laguna B, Soderlund KA, et al. Spinal Compliance Curves: Preliminary Experience with a New Tool for Evaluating Suspected CSF Venous Fistulas on CT Myelography in Patients with Spontaneous Intracranial Hypotension. AJNR Am J Neuroradiol. 2021. PMID: 33602750. doi:10.3174/ajnr.A7018
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。