文献速递神经CT

3毫米与2毫米最大密度投影CT血管成像检测急性前循环卒中患者颅内大血管闭塞的可靠性与准确性

Reliability and accuracy of 3-mm and 2-mm maximum intensity projection CT angiography to detect intracranial large vessel occlusion in patients with acute anterior cerebral circulation stroke.
PubMed 文献 · Neuroradiology · 2021-02-03

研究纳入140例急性卒中患者(41例有大血管闭塞,99例无),由两名神经放射科医生使用轴位3毫米和2毫米最大密度投影(MIP)CT血管成像评估大血管闭塞。3毫米MIP的观察者间一致性为实质性(ĸ=0.67),2毫米MIP为几乎完全一致(ĸ=0.82);两者敏感度和特异度无统计学显著差异(P≥0.375)。结论认为厚层(2-3毫米)轴位MIP不适用于检测前循环近端大血管闭塞。

要点

  • 2毫米MIP观察者间一致性(ĸ=0.82)优于3毫米MIP(ĸ=0.67)。
  • 3毫米与2毫米MIP的敏感度和特异度无统计学显著差异(P≥0.375)。
  • 孤立性M2段闭塞在3毫米MIP上漏诊率最高达60.0%,2毫米MIP上达40.0%。

核心结论

  • 厚层(2-3毫米)轴位MIP不适用于检测前循环近端大血管闭塞。

研究设计与样本

  • 共纳入140例急性卒中患者,其中41例有大血管闭塞、99例无大血管闭塞。
  • 由两名神经放射科医生使用轴位3毫米和2毫米MIP CT血管成像评估大血管闭塞。

诊断标准与关键数值

  • 3毫米MIP观察者间一致性ĸ=0.67;2毫米MIP观察者间一致性ĸ=0.82。
  • 3毫米MIP:观察者1敏感度80.5%、特异度98.0%;观察者2敏感度68.3%、特异度96.0%。
  • 2毫米MIP:观察者1敏感度82.9%、特异度98.0%;观察者2敏感度73.2%、特异度99.0%。
  • 3毫米与2毫米MIP的敏感度和特异度无统计学显著差异(P≥0.375)。
  • 远端颅内颈动脉和/或M1段闭塞的正确识别率:观察者1使用3毫米MIP为96.0%,观察者2使用3毫米MIP为88.0%,观察者1使用2毫米MIP为96.0%,观察者2使用2毫米MIP为96.0%。

临床应用与阅片要点

  • 孤立性M2段闭塞漏诊率:3毫米MIP观察者1为7/15(46.7%)、观察者2为9/15(60.0%);2毫米MIP观察者1为5/15(33.3%)、观察者2为6/15(40.0%)。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: To evaluate the reliability and accuracy of thick maximum intensity projection (MIP) CTA images to detect large-vessel occlusion (LVO) in the anterior circulation in patients with acute stroke.

METHODS: A total of 140 acute stroke patients (41 with and 99 without LVO) were evaluated by two neuroradiologists for LVO using axial 3-mm and 2-mm MIPs.

RESULTS: Interobserver agreement was substantial using 3-mm MIPs (ĸ = 0.67) and almost perfect using 2-mm MIPs (ĸ = 0.82). Using 3-mm MIPs, sensitivities were 80.5% and 68.3%, with specificities of 98.0% and 96.0%. Using 2-mm MIPs, sensitivities were 82.9% and 73.2%, with specificities of 98.0% and 99.0%. Sensitivity and specificity of 3 mm and 2 mm MIPs were not statistically significantly different (P ≥ 0.375). The majority of LVOs in the distal intracranial carotid artery, and/or M1-segment were correctly identified: 96.0% (observer 1, 3-mm MIPs), 88.0% (observer 2, 3-mm MIPs), 96.0% (observer 1, 2-mm MIPs), and 96.0% (observer 2, 2 mm MIPs). Using 3-mm MIP images, observers 1 and 2 missed 7/15 (46.7%) and 9/15 (60.0%) of isolated M2-segment occlusions, respectively. Using 2-mm MIP images, observers 1 and 2 missed 5/15 (33.3%) and 6/15 (40.0%) of isolated M2-segment occlusions, respectively.

CONCLUSION: Thick (2-3 mm) axial MIPs are not useful to detect proximal LVO in the anterior circulation.

来源:Neuroradiology,查看原文。版权归原作者所有。

引用

  1. Fasen BACM, Borghans RAP, Heijboer RJJ, et al. Reliability and accuracy of 3-mm and 2-mm maximum intensity projection CT angiography to detect intracranial large vessel occlusion in patients with acute anterior cerebral circulation stroke. Neuroradiology. 2021. PMID: 33533946. doi:10.1007/s00234-021-02659-1

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。