脑肿瘤术后异物肉芽肿与真性复发肿瘤鉴别诊断的MRI表现
本研究纳入22例既往脑肿瘤手术患者,再手术病理证实8例为异物肉芽肿(FBG)、14例为真性复发肿瘤(RT),比较再次手术前MRI表现。FBG较RT病灶更小,T2WI低信号、DWI无弥散受限及增强T1WI「环与泡」征更常见;将瘤床病灶MRI表现与原肿瘤对比有助于提高诊断信心。
要点
- FBG平均病灶大小1.3±0.7 cm,小于RT的3.2±1.7 cm(p=0.001,OR=4.18)。
- T2WI低信号FBG为6/8(75%),RT为0/14(0%;p<0.001,OR=75.4)。
- 增强T1WI「环与泡」征FBG为7/8(87.5%),RT为2/14(14.3%;p=0.001,OR=42)。
局限性
- 原文未报告局限性
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
AIM: To evaluate the postoperative magnetic resonance imaging (MRI) findings of intracranial foreign body granulomas (FBGs) and true recurrent tumours (RTs) and thus lead to a basis for management decision-making.
MATERIALS AND METHODS: Twenty-two patients with previous brain tumour surgery were diagnosed clinically with RT and underwent surgery. Re-operative pathology revealed FBG in eight patients and RT in 14 patients. MRI findings before the initial operation were compared to those before the re-operation.
RESULTS: Features of FBGs versus RTs on MRI were as follows: (1) mean lesion size: 1.3 ± 0.7 (0.5-2.6) versus 3.2 ± 1.7 (1.1-6.3) cm (p=0.001, odds ratio [OR] = 4.18); (2) hypointensity on T2-weighted imaging (WI): 6/8 (75%) versus 0/14 (0%; p<0.001, OR=75.4); (3) non-restricted diffusion on diffusion-WI (DWI): 6/8 (75%) versus 2/14 (14.3%; p=0.008, OR=18); and (4) "ring and bubble" appearance on contrast-enhanced T1WI: 7/8 (87.5%) versus 2/14 (14.3%; p=0.001, OR=42). In comparison with their original tumours, the FBGs in the FBG group showed significantly lower T2 signal intensity, lower signal on DWI, and more cases of non-restricted diffusion on DWI (p=0.04, 0.04, 0.04, respectively).
CONCLUSION: On brain MRI, FBGs can be differentiated from RTs by their relatively smaller size, hypointensity on T2WI, lack of restricted diffusion on DWI, and "ring and bubble" appearance on contrast-enhanced T1WI. Comparing the MRI findings of the focal lesion in the tumour bed with those of the original tumour is suggested to enhance diagnostic confidence.
引用
- Lin LY, Lin SC, Lee HJ, et al. MRI findings for diagnosis of postoperative foreign body granulomas versus recurrent tumours in patients of brain tumour surgery. Clin Radiol. 2021. PMID: 33551151. doi:10.1016/j.crad.2020.12.018
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。