文献速递神经技术与安全CT

颅骨对脑CT成像的影响:颅骨与脑体模研究

The effects of the skull on CT imaging of the brain: a skull and brain phantom study.
PubMed 文献 · Br J Radiol · 2021-02-03

研究通过临床病例回顾和颅骨-脑体模实验,探讨颅骨束硬化对脑组织CT值测量的影响,并验证单色X线源能否减轻该效应。结果显示,X线穿过颅骨时脑组织HU值持续降低,多色X线源下体模可见此效应而虚拟单色X线源下消失。结论认为颅骨束硬化降低脑组织HU测量值,可能影响定量成像,虚拟单色X线源或可减轻该效应。

要点

  • X线穿过颅骨时,脑组织CT值(HU)较未穿过颅骨时持续降低。
  • 颅骨-脑体模在多色X线源下可见束硬化效应,虚拟单色X线源下该效应消失。
  • 颅骨束硬化可影响脑组织定量成像,虚拟单色X线源可能减轻该效应。

关键影像表现/征象

  • 临床病例中,X线束穿过颅骨时脑组织HU值持续低于未穿过颅骨时。
  • 人颅骨-脑体模进一步展示该效应,多色X线源下明显,虚拟单色X线源下未出现。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: To investigate the effects of beam hardening by the skull on the measured radiodensity of the brain. To test a hypothesis that these effects of beam hardening are decreased using a monochromatic energy source.

METHODS: Selected clinical cases were reviewed in illustration. An anthropomorphic skull and brain phantom was created and scanned in a clinical CT scanner with skull, without skull, and with hemicraniectomy. The effects of beam hardening were illustrated by scanning the phantom with mono- and poly-chromatic X-ray sources.

RESULTS: In clinical cases, the HU values of the brain were consistently lower when the X-ray beam traversed the skull than when it did not. An anthropomorphic skull-and-brain phantom further demonstrated these effects, which were evident with a polychromatic energy source and absent with a virtual monochromatic energy source.

CONCLUSIONS: Beam hardening by the skull lowers the measured HU values of the brain. The effects, which can impact quantitative imaging, may be mitigated by a virtual monochromatic energy source.

ADVANCES IN KNOWLEDGE: Beam hardening by the skull lowers the measured radiodensity of the brain. The effects may be mitigated by a virtual monochromatic energy source.