高分辨率血管壁成像与时间飞跃法MR血管成像评估颅内动脉狭窄程度的可重复性及与DSA的诊断一致性

Quantification of intracranial arterial stenotic degree evaluated by high-resolution vessel wall imaging and time-of-flight MR angiography: reproducibility, and diagnostic agreement with DSA.
PubMed 文献 · Eur Radiol · 2021-02-14

该回顾性研究纳入106例疑似颅内动脉疾病患者的246处狭窄病变,比较HR-VWI与TOF-MRA评估颅内动脉狭窄程度的可重复性及与DSA的诊断一致性。HR-VWI的观察者内和观察者间可重复性均优异且优于TOF-MRA,与DSA的总体一致性CCC=0.932,TOF-MRA为0.694,HR-VWI还可提供额外的血管壁信息。

要点

  • HR-VWI评估颅内动脉狭窄的可重复性优异,且优于TOF-MRA。
  • HR-VWI与DSA诊断一致性CCC=0.932,TOF-MRA为0.694。
  • HR-VWI除评估狭窄外还可提供额外的血管壁信息。

关键影像表现/征象

  • HR-VWI可评估颅内动脉狭窄程度并提供额外的血管壁信息。

诊断标准与关键数值

  • HR-VWI与DSA的总体一致性CCC=0.932,TOF-MRA与DSA的总体一致性CCC=0.694。
  • HR-VWI识别狭窄的观察者内和观察者间总可重复性均优异,且优于TOF-MRA。

临床应用与阅片要点

  • HR-VWI评估颅内动脉狭窄的可重复性优于TOF-MRA,与DSA诊断一致性更高。
  • HR-VWI除评估血管狭窄外可提供额外血管壁信息,有助于临床诊断和管理。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: The purpose of this study was to compare the reproducibility and diagnostic agreement of high-resolution vessel wall imaging (HR-VWI) and time-of-flight magnetic resonance angiography (TOF-MRA) with digital subtraction angiography (DSA) to evaluate intracranial arterial stenosis.

METHODS: We retrospectively enrolled patients who underwent HR-VWI and TOF-MRA with suspected intracranial artery disease and had DSA results from our institutional imaging database. Two neuroradiologists separately and independently evaluated anonymous image data for the stenotic lesions. DSA was analyzed by two neurointerventionalists and it served as a standard criterion. The reproducibility of these two MR techniques was determined by the intraclass correlation coefficients (ICCs). The diagnostic agreement to DSA was assessed by the concordance correlation coefficients (CCCs).

RESULTS: A total of 246 lesions from 106 individuals were analyzed for stenotic degrees. The total intra-observer and inter-observer reproducibility of HR-VWI was excellent for identifying stenosis and better than of TOF-MRA. The overall concordance of HR-VWI with DSA was excellent with CCC = 0.932, whereas TOF-MRA was 0.694. In addition, HR-VWI could provide additional vessel wall information.

CONCLUSIONS: HR-VWI has more advantages over TOF-MRA, such as better reproducibilities and diagnostic agreements with DSA to analyze intracranial arterial stenosis. It provides additional information that helps in clinical diagnosis and management.

KEY POINTS: • High-resolution vessel wall imaging can assess intracranial arterial stenosis with a better reproducibility than TOF-MRA and has a higher diagnostic agreement with DSA. • High-resolution vessel wall imaging had a higher diagnostic agreement with DSA compared with TOF-MRA. • Apart from evaluating vascular stenosis, HR-VWI provided additional vessel wall information to help in clinical diagnosis.

来源:Eur Radiol,查看原文。版权归原作者所有。

引用

  1. Gong Y, Cao C, Guo Y, et al. Quantification of intracranial arterial stenotic degree evaluated by high-resolution vessel wall imaging and time-of-flight MR angiography: reproducibility, and diagnostic agreement with DSA. Eur Radiol. 2021. PMID: 33585995. doi:10.1007/s00330-021-07719-x

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。