文献速递心血管外周血管MR

使用加速多VENC 4D血流心脏磁共振对44名健康志愿者进行速度定量

Velocity quantification in 44 healthy volunteers using accelerated multi-VENC 4D flow CMR.
PubMed 文献 · Eur J Radiol · 2021-01-29

研究纳入44名健康志愿者,在3T磁共振上采用k-t加速多VENC 4D血流序列采集主心脏周围血管,并与单VENC(200 cm/s)比较。多VENC组升主动脉与主肺动脉每搏输出量差值显著低于单VENC组(9.6±7.8 mL vs 25.4±26.4 mL,p<0.001),平均扫描时间13.8±4 min,流速与每搏输出量值与既往文献一致。

要点

  • 多VENC 4D血流可降低升主动脉与主肺动脉每搏输出量差值,优于单VENC。
  • 平均扫描时间13.8±4 min,在临床可接受范围内。
  • 不同流速或复杂血流现象血管评估时多VENC可能更有价值。

诊断标准与关键数值

  • 多VENC组升主动脉与主肺动脉每搏输出量差值为9.6±7.8 mL,单VENC组为25.4±26.4 mL,多VENC组显著更低(p<0.001)。
  • 升主动脉和肺动脉上下游感兴趣区之间的每搏输出量差值同样在多VENC组显著低于单VENC组。
  • 平均和最大流速及每搏输出量值与既往研究一致。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

BACKGROUND: To evaluate the feasibility of a k-t accelerated multi-VENC 4D phase contrast flow MRI acquisition of the main heart-surrounding vessels, its benefits over a traditional single-VENC acquisition and to present reference flow and velocity values in a large cohort of volunteers.

METHODS: 44 healthy volunteers were examined on a 3 T MRI scanner (Ingenia, Philips, Best, The Netherlands). 4D flow measurements were obtained with a FOV including the aorta and the pulmonary arteries. VENC values were set to 40, 100 and 200 cm/s and unfolded based on an MRI signal model. Unfolded multi-VENC data was compared to the single-VENC with VENC 200 cm/s. Flow and velocity quantification was performed in several regions of interest (ROI) placed in the ascending aorta and in the main pulmonary artery. Conservation of mass analysis was performed for single- and multi-VENC datasets. Values for mean and maximal flow velocity and stroke volume were calculated and compared to the literature.

RESULTS: Mean scan time was 13.8 ± 4 min. Differences between stroke volumes between the ascending aorta and the main pulmonary artery were significantly lower in multi-VENC datasets compared to single-VENC datasets (9.6 ± 7.8 mL vs. 25.4 ± 26.4 mL, p < 0.001). This was also true for differences in stroke volume between up- and downstream ROIs in the ascending aorta and pulmonary artery. Values for mean and maximal velocities and stroke volume were in-line with previous studies. To highlight potential clinical applications two exemplary 4D flow measurements in patients with different pathologies are shown and compared to single-VENC datasets.

CONCLUSIONS: k-t accelerated multi-VENC 4D phase contrast flow MRI acquisition of the great vessels is feasible in a clinically acceptable scan duration. It offers improvements over traditional single-VENC 4D flow, expectedly being valuable when vessels with different flow velocities or complex flow phenomena are evaluated.

来源:Eur J Radiol,查看原文。版权归原作者所有。

引用

  1. Kroeger JR, Pavesio FC, Mörsdorf R, et al. Velocity quantification in 44 healthy volunteers using accelerated multi-VENC 4D flow CMR. Eur J Radiol. 2021. PMID: 33596498. doi:10.1016/j.ejrad.2021.109570

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。