DISORDER评估:儿科场景下容积脑MRI的回顾性图像运动校正
研究在32例未镇静儿童(含7例癫痫,2-18岁)中于3T前瞻性采集3D MPRAGE、T2-TSE和FLAIR,采用DISORDER技术做回顾性运动校正并比较三种重建。梯度熵与MPRAGE白质均匀性两客观指标均改善,且改善与扫描内运动量相关;两名神经放射学家盲法评分认为校正后图像质量更高(Wilcoxon z:MPRAGE -3.164、TSE -2.066、FLAIR -2.645,均P<.05)。
要点
- DISORDER回顾性运动校正可提升未镇静儿童3D脑MRI的客观与主观图像质量。
- 图像质量改善与扫描内运动量相关。
- 75%的检查中至少1个序列经该技术获得改善。
英文原文(摘要)· 点击展开
BACKGROUND AND PURPOSE: Head motion causes image degradation in brain MR imaging examinations, negatively impacting image quality, especially in pediatric populations. Here, we used a retrospective motion correction technique in children and assessed image quality improvement for 3D MR imaging acquisitions.
MATERIALS AND METHODS: We prospectively acquired brain MR imaging at 3T using 3D sequences, T1-weighted MPRAGE, T2-weighted TSE, and FLAIR in 32 unsedated children, including 7 with epilepsy (age range, 2-18 years). We implemented a novel motion correction technique through a modification of k-space data acquisition: Distributed and Incoherent Sample Orders for Reconstruction Deblurring by using Encoding Redundancy (DISORDER). For each participant and technique, we obtained 3 reconstructions as acquired (Aq), after DISORDER motion correction (Di), and Di with additional outlier rejection (DiOut). We analyzed 288 images quantitatively, measuring 2 objective no-reference image quality metrics: gradient entropy (GE) and MPRAGE white matter (WM) homogeneity. As a qualitative metric, we presented blinded and randomized images to 2 expert neuroradiologists who scored them for clinical readability.
RESULTS: Both image quality metrics improved after motion correction for all modalities, and improvement correlated with the amount of intrascan motion. Neuroradiologists also considered the motion corrected images as of higher quality (Wilcoxon z = -3.164 for MPRAGE; z = -2.066 for TSE; z = -2.645 for FLAIR; all P < .05).
CONCLUSIONS: Retrospective image motion correction with DISORDER increased image quality both from an objective and qualitative perspective. In 75% of sessions, at least 1 sequence was improved by this approach, indicating the benefit of this technique in unsedated children for both clinical and research environments.
引用
- Vecchiato K, Egloff A, Carney O, et al. Evaluation of DISORDER: Retrospective Image Motion Correction for Volumetric Brain MRI in a Pediatric Setting. AJNR Am J Neuroradiol. 2021. PMID: 33602745. doi:10.3174/ajnr.A7001
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。