文献速递神经头颈MR

三维黑血增强磁共振成像上的明显强化:颅内动脉狭窄与完全闭塞的比较

Strong enhancement on three-dimensional black-blood enhanced magnetic resonance imaging: Comparison intracranial stenosis and complete occlusion.
PubMed 文献 · Eur J Radiol · 2021-02-07

回顾性分析2018年1月至2020年1月因非创伤性脑病变就诊的92例患者的三维黑血增强MR成像和MR血管成像资料,按MR血管成像所见分为完全闭塞组33例、重度狭窄组36例和轻度狭窄组23例。完全闭塞组表现为同心性和节段性强化,重度狭窄组常见同心性和局灶性强化;完全闭塞组的高信号血管征显著高于狭窄组(p<0.001),病变与垂体对比度比值显著低于狭窄组(p<0.05)。

要点

  • 完全闭塞组在三维黑血增强MR成像上呈同心性和节段性强化,高信号血管征较狭窄组更常见(p<0.001)。
  • 重度狭窄组更常见同心性和局灶性强化,与完全闭塞组的强化形态不同。
  • 完全闭塞组病变与垂体对比度比值显著低于狭窄组(p<0.05),提示强化程度相对较低。

关键影像表现/征象

  • 完全闭塞组在三维黑血增强MR成像上表现为同心性和节段性强化。
  • 重度狭窄组常见同心性和局灶性强化。
  • 完全闭塞组的高信号血管征显著高于狭窄组(p<0.001)。
  • 完全闭塞组病变与垂体的对比度比值显著低于狭窄组(p<0.05)。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: The purpose of this study was to evaluate contrast enhancement patterns on three-dimensional (3D) black blood (BB) contrast-enhanced magnetic resonance (MR) imaging in patients with occlusion or stenosis of the anterior intracranial artery.

MATERIALS AND METHODS: From January 2018 to January 2020 we retrospectively reviewed stroke 3D BB contrast-enhanced MR imaging and MR angiography findings of patients visiting the emergency room for evaluation of non-traumatic brain lesions. In total, 92 patients with positive findings on 3D BB contrast-enhanced MR imaging were enrolled in this study. We divided the enrolled group according to whether MR angiography findings suggested complete occlusion, high-grade stenosis (51-99 %), or low-grade stenosis (10-50 %).

RESULTS: Of 92 patients, 33 had complete occlusion in the anterior intracranial artery, 36 had high-grade stenosis, and 23 had low-grade stenosis. The complete occlusion group showed concentric and segmental enhancement on 3D BB enhanced MR imaging. The high-grade stenosis group frequently showed concentric and focal enhancement. The high signal vessel sign in the complete occlusion group was significantly higher compared to the stenosis group (p < 0.001). The contrast ratio between the lesion and pituitary gland in the occlusion group was significantly lower than that of the stenosis group (p < 0.05).

CONCLUSION: Bright contrast enhancement and high signal vessel sign on 3D BB contrast enhanced MR imaging are related to contrast stagnation of the occlusion site and slow flow of a distal portion of the occlusion site.

来源:Eur J Radiol,查看原文。版权归原作者所有。

引用

  1. Gang M, Lee H, Kwak HS, et al. Strong enhancement on three-dimensional black-blood enhanced magnetic resonance imaging: Comparison intracranial stenosis and complete occlusion. Eur J Radiol. 2021. PMID: 33610077. doi:10.1016/j.ejrad.2021.109580

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。