双层探测器双能CT虚拟单能图像用于检出脑肿瘤的图像质量评估
回顾性纳入32例脑肿瘤患者,比较双层探测器双能CT生成的虚拟单能图像(40–200 keV)与常规多能图像的客观及主观质量。40 keV图像噪声低于常规图像,肿瘤与白质间对比度及CNR显著更高,对比度、边缘和诊断信心主观评分亦显著更高。
要点
- 40 keV虚拟单能图像噪声低于常规CT图像,肿瘤与白质对比度和CNR显著更高。
- 40 keV图像对肿瘤对比度、边缘及诊断信心的主观评分显著高于常规图像。
- 肿瘤与灰质间对比度和CNR在40 keV与常规图像间无显著差异。
关键影像表现/征象
- 所有测试能级虚拟单能图像的图像噪声均显著低于常规CT图像(p < 0.05)。
- 40 keV虚拟单能图像获得最佳CNR。
- 40 keV图像肿瘤与白质间对比度和CNR均显著高于常规CT图像(p < 0.001)。
- 40 keV图像肿瘤与灰质间对比度和CNR与常规CT图像无显著差异(p = 0.47和p = 0.31)。
诊断标准与关键数值
- 以40–200 keV(间隔10 keV)虚拟单能图像中CNR最高者定义为优化虚拟单能图像,本研究中为40 keV。
- 主观评估采用4分制,评估对比度、边缘、噪声、伪影和诊断信心。
- 40 keV图像对比度、边缘和诊断信心的主观评分显著高于常规CT图像(p < 0.01)。
临床应用与阅片要点
- 阅片时可关注40 keV虚拟单能图像对白质区脑肿瘤对比度和诊断信心的提升。
- 肿瘤与灰质间对比度和CNR在40 keV与常规图像间无显著差异。
局限性
- 原文未报告局限性
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE: To evaluate the usefulness of virtual monochromatic images (VMIs) obtained using dual-layer dual-energy CT (DL-DECT) for evaluating brain tumors.
MATERIALS AND METHODS: This retrospective study included 32 patients with brain tumors who had undergone non-contrast head CT using DL-DECT. Among them, 15 had glioblastoma (GBM), 7 had malignant lymphoma, 5 had high-grade glioma other than GBM, 3 had low-grade glioma, and 2 had metastatic tumors. Conventional polychromatic images and VMIs (40-200 keV at 10 keV intervals) were generated. We compared CT attenuation, image noise, contrast, and contrast-to-noise ratio (CNR) between tumor and white matter (WM) or grey matter (GM) between VMIs showing the highest CNR (optimized VMI) and conventional CT images using the paired t test. Two radiologists subjectively assessed the contrast, margin, noise, artifact, and diagnostic confidence of optimized VMIs and conventional images on a 4-point scale.
RESULTS: The image noise of VMIs at all energy levels tested was significantly lower than that of conventional CT images (p < 0.05). The 40-keV VMIs yielded the best CNR. Furthermore, both contrast and CNR between the tumor and WM were significantly higher in the 40 keV images than in the conventional CT images (p < 0.001); however, the contrast and CNR between tumor and GM were not significantly different (p = 0.47 and p = 0.31, respectively). The subjective scores assigned to contrast, margin, and diagnostic confidence were significantly higher for 40 keV images than for conventional CT images (p < 0.01).
CONCLUSION: In head CT for patients with brain tumors, compared with conventional CT images, 40 keV VMIs from DL-DECT yielded superior tumor contrast and diagnostic confidence, especially for brain tumors located in the WM.
引用
- Tanoue S, Nakaura T, Nagayama Y, et al. Virtual Monochromatic Image Quality from Dual-Layer Dual-Energy Computed Tomography for Detecting Brain Tumors. Korean J Radiol. 2021. PMID: 33569932. doi:10.3348/kjr.2020.0677
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。