化学交换依赖性饱和转移MRI对痴呆诊断的附加价值
本研究为横断面前瞻性研究,纳入41名受试者(痴呆19例、非痴呆22例),采用三维梯度自旋回波序列获取全脑CEST数据,通过六池洛伦兹拟合计算酰胺、胺、羟基及MTRasym等指标。结果显示痴呆组海马胺信号及3 ppm、3.5 ppm处MTRasym值显著高于非痴呆组,多数CEST指标与MMSE评分显著相关;将CEST指标加入灰质体积可改善组间分类,其中前扣带回2 ppm处MTRasym的AUC达0.981,敏感度100%、特异度90.91%。
要点
- 痴呆组海马胺信号及3 ppm、3.5 ppm处MTRasym值显著高于非痴呆组。
- 多数CEST指标与MMSE评分显著相关,但与灰质体积多无显著相关。
- 前扣带回2 ppm处MTRasym联合灰质体积分类AUC达0.981。
关键影像表现/征象
- 海马胺信号痴呆组0.046 vs 非痴呆组0.029,P=0.011。
- 海马3 ppm处MTRasym值痴呆组1.138 vs 非痴呆组0.748,P=0.022。
- 海马3.5 ppm处MTRasym值痴呆组0.875 vs 非痴呆组0.463,P=0.029。
诊断标准与关键数值
- 前扣带回2 ppm处MTRasym值联合灰质体积分类痴呆与非痴呆的AUC=0.981,敏感度100%、特异度90.91。
临床应用与阅片要点
- 多数CEST指标的分类能力低于灰质体积,但将任一CEST指标加入灰质体积可改善受试者组间分类。
- 作者认为CEST MRI可能在未来提供新的影像生物标志物,用于无创监测阿尔茨海默病不同疾病状态。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE: Chemical exchange-dependent saturation transfer (CEST) MRI is sensitive for detecting solid-like proteins and may detect changes in the levels of mobile proteins and peptides in tissues. The objective of this study was to evaluate the characteristics of chemical exchange proton pools using the CEST MRI technique in patients with dementia.
MATERIALS AND METHODS: Our institutional review board approved this cross-sectional prospective study and informed consent was obtained from all participants. This study included 41 subjects (19 with dementia and 22 without dementia). Complete CEST data of the brain were obtained using a three-dimensional gradient and spin-echo sequence to map CEST indices, such as amide, amine, hydroxyl, and magnetization transfer ratio asymmetry (MTRasym) values, using six-pool Lorentzian fitting. Statistical analyses of CEST indices were performed to evaluate group comparisons, their correlations with gray matter volume (GMV) and Mini-Mental State Examination (MMSE) scores, and receiver operating characteristic (ROC) curves.
RESULTS: Amine signals (0.029 for non-dementia, 0.046 for dementia, p = 0.011 at hippocampus) and MTRasym values at 3 ppm (0.748 for non-dementia, 1.138 for dementia, p = 0.022 at hippocampus), and 3.5 ppm (0.463 for non-dementia, 0.875 for dementia, p = 0.029 at hippocampus) were significantly higher in the dementia group than in the non-dementia group. Most CEST indices were not significantly correlated with GMV; however, except amide, most indices were significantly correlated with the MMSE scores. The classification power of most CEST indices was lower than that of GMV but adding one of the CEST indices in GMV improved the classification between the subject groups. The largest improvement was seen in the MTRasym values at 2 ppm in the anterior cingulate (area under the ROC curve = 0.981), with a sensitivity of 100 and a specificity of 90.91.
CONCLUSION: CEST MRI potentially allows noninvasive image alterations in the Alzheimer's disease brain without injecting isotopes for monitoring different disease states and may provide a new imaging biomarker in the future.
引用
- Oh JH, Choi BG, Rhee HY, et al. Added Value of Chemical Exchange-Dependent Saturation Transfer MRI for the Diagnosis of Dementia. Korean J Radiol. 2020. PMID: 33543845. doi:10.3348/kjr.2020.0700
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。