文献速递神经MR

3T场强下缺血性卒中弥散加权成像:合成b值的价值

Diffusion-weighted MRI of ischemic stroke at 3T: Value of synthetic b-values.
PubMed 文献 · Br J Radiol · 2021-02-17

研究纳入36例症状发作24小时内DWI显示弥散异常的急性缺血性卒中患者,在3T下采集b=0、500、1000、2000 s mm⁻²图像并计算合成b=1000、1500、2000、2500 s mm⁻²图像,比较合成与采集高b值图像相对采集b=1000 s mm⁻²图像在病灶检出率、图像质量、不确定高信号和病灶显著性方面的表现。合成b=1000和1500图像与采集b=1000图像在病灶检出率、图像质量和不确定高信号方面相当,但病灶显著性显著改善(p<0.01),且常被选为 preferred b值;采集b=2000图像病灶检出率相似、病灶显著性改善(p<0.01)但图像质量更差(p<0.01);合成b=2000和2500图像在多数或所有类别上显著差于采集b=1000图像(p<0.01)。

要点

  • 合成b=1000和1500 s mm⁻²图像与采集b=1000图像病灶检出率相当,病灶显著性显著改善(p<0.01)。
  • 采集b=2000 s mm⁻²图像病灶检出率与采集b=1000相似、病灶显著性改善(p<0.01),但图像质量更差(p<0.01)。
  • 合成b=2000和2500 s mm⁻²图像在多数或所有评价类别上显著差于采集b=1000图像(p<0.01)。

诊断标准与关键数值

  • 合成b=1000和1500 s mm⁻²图像与采集b=1000 s mm⁻²图像在病灶检出率、图像质量和不确定高信号方面相当,但病灶显著性显著改善(p<0.01)。
  • 采集b=2000 s mm⁻²图像与采集b=1000 s mm⁻²图像病灶检出率相似、病灶显著性改善(p<0.01),但图像质量更差(p<0.01)。
  • 合成b=2000和2500 s mm⁻²图像在多数或所有类别上显著差于采集b=1000 s mm⁻²图像(p<0.01)。
  • 对比度比(CR)随b值增加而显著升高。

临床应用与阅片要点

  • 作者认为合成b=1000和1500 s mm⁻²图像及采集b=2000 s mm⁻²图像可能因病灶显著性改善而具有临床价值。
  • 合成b=2000和2500 s mm⁻²图像在多数或所有评价类别上显著差于采集b=1000 s mm⁻²图像(p<0.01)。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: Diffusion-weighted imaging (DWI) plays a crucial role in the diagnosis of ischemic stroke. We assessed the value of computed and acquired high b-value DWI in comparison with conventional b = 1000 s mm-2 DWI for ischemic stroke at 3T.

METHODS: We included 36 patients with acute ischemic stroke who presented with diffusion abnormalities on DWI performed within 24 h of symptom onset. B-values of 0, 500, 1000 and 2000 s mm-2 were acquired. Synthetic images with b-values of 1000, 1500, 2000 and 2500 s mm-2 were computed. Two readers compared synthetic (syn) and acquired (acq) b = 2000 s mm-2 images with acquired b = 1000 s mm-2 images in terms of lesion detection rate, image quality, presence of uncertain hyperintensities and lesion conspicuity. Readers also selected their preferred b-value. Contrast ratio (CR) measurements were performed. Non-parametrical statistical tests and weighted Cohens' κ tests were computed.

RESULTS: Syn1000 and syn1500 matched acq1000 images in terms of lesion detection rate, image quality and presence of uncertain hyperintensities but presented with significantly improved lesion conspicuity (p < 0.01) and were frequently selected as preferred b-values. Acq2000 images exhibited a similar lesion detection rate and improved lesion conspicuity (p < 0.01) but worse image quality (p < 0.01) than acq1000 images. Syn2000 and syn2500 images performed significantly worse (p < 0.01) than acq1000 images in most or all categories. CR significantly increased with increasing b-values.

CONCLUSION: Synthetic images at b = 1000 and 1500 s mm-2 and acquired DWI images at b = 2000 s mm-2 may be of clinical value due to improved lesion conspicuity.

ADVANCES IN KNOWLEDGE: Synthetic b-values enable improved lesion conspicuity for DWI of ischemic stroke.

来源:Br J Radiol,查看原文。版权归原作者所有。

引用

  1. Sartoretti T, Sartoretti E, Wyss M, et al. Diffusion-weighted MRI of ischemic stroke at 3T: Value of synthetic b-values. Br J Radiol. 2021. PMID: 33596102. doi:10.1259/bjr.20200869

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。