文献速递神经MR

特发性正常压力脑积水中胼胝体角测量:冠状面小角度旋转偏差影响测量可靠性

Callosal angle in idiopathic normal pressure hydrocephalus: small angular mal-rotations of the coronal plane affect measurement reliability.
PubMed 文献 · Neuroradiology · 2021-02-05

本研究在特发性正常压力脑积水患者与健康对照的三维等体素T1加权脑MRI上,由两名独立评估者按标准真冠状面测量胼胝体角,并评估冠状面在前后方向及顺时针-逆时针方向±5°和±10°旋转偏差对测量值及评估者间信度(ICC)的影响。真冠状面上评估者间ICC在患者组为0.973、对照组为0.875;旋转偏差下对照组ICC(0.484-0.886)低于患者组(0.879-0.981),顺时针-逆时针方向(0.484-0.956)低于前后方向(0.503-0.981)。旋转导致的胼胝体角变化在患者组显著(P < 0.0001至0.0378),对照组不显著(P > 0.1)。

要点

  • 真冠状面上胼胝体角评估者间ICC在特发性正常压力脑积水患者为0.973、对照为0.875。
  • 冠状面旋转偏差下对照组ICC为0.484-0.886,低于患者组的0.879-0.981。
  • 旋转所致胼胝体角变化在患者组显著(P < 0.0001至0.0378),对照组不显著(P > 0.1)。

诊断标准与关键数值

  • 真冠状面上胼胝体角评估者间ICC在特发性正常压力脑积水患者为0.973、在对照为0.875。
  • 冠状面旋转偏差设置下胼胝体角ICC在对照组为0.484-0.886、在患者组为0.879-0.981。
  • 冠状面旋转偏差设置下胼胝体角ICC在顺时针-逆时针方向为0.484-0.956、在前后方向为0.503-0.981。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: The callosal angle (CA) is a useful biomarker in the diagnosis and management of idiopathic normal pressure hydrocephalus (NPH). Used incorrectly, CA measurements are variable, affecting its reliability as a clinical tool. Our objectives are to evaluate (i) reproducibility of established CA measurements between trained raters and (ii) impact of minor angular mal-rotations of the true coronal plane on CA measurements.

METHODS: CAs were measured by two independent raters on three-dimensional isovolumetric T1-weighted brain MRI of NPH patients and healthy controls using the established true coronal plane reformatted orthogonal to the plane containing the anterior-posterior commissural (AC-PC) line at the level of the posterior commissure. CA changes were subsequently evaluated when the coronal plane was mal-rotated by ± 5° and ± 10° in anterior-posterior and clockwise-anticlockwise directions. Inter-rater reliability of CA measurements was assessed using the intraclass correlation coefficient (ICC).

RESULTS: On the true coronal plane, inter-rater ICC was excellent (0.973) for NPH patients and good (0.875) for controls. On mal-rotated coronal plane setups, ICC for CA was worse in controls (0.484-0.886) than NPH (0.879-0.981) groups and in clockwise-anticlockwise (0.484-0.956) than anterior-posterior (0.503-0.981) mal-rotations. CA changes secondary to mal-rotations from the true coronal plane were significant in NPH patients (P < 0.0001 to 0.0378) but not in controls (P > 0.1).

CONCLUSION: This is the first demonstration of how small angular mal-rotations of the coronal plane used for CA measurement affect its value and inter-rater reliability, highlighting the importance of a standardized protocol when measuring the CA in NPH workup.

来源:Neuroradiology,查看原文。版权归原作者所有。

引用

  1. Lee W, Lee A, Li H, et al. Callosal angle in idiopathic normal pressure hydrocephalus: small angular mal-rotations of the coronal plane affect measurement reliability. Neuroradiology. 2021. PMID: 33544172. doi:10.1007/s00234-021-02658-2

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。