本研究以组织病理学为参考标准,在24例确诊克罗恩病的儿童中评估40个肠段,比较常规超声联合彩色多普勒、主观及定量超声造影对疾病活动度的诊断效能。定量超声造影的峰值增强值预测中重度炎症的敏感度为72.2%、特异度为100%、诊断准确率为87.5%。作者认为定量超声造影有潜力成为评估儿童克罗恩病活动度的补充方法,纤维化可能影响峰值增强结果并低估炎症活动。

要点

  • 定量超声造影峰值增强值预测中重度炎症特异度达100%,敏感度72.2%。
  • 主观超声造影敏感度77.8%、特异度77.3%,常规超声联合彩色多普勒敏感度55.6%。
  • 纤维化可能影响峰值增强结果并低估炎症活动,判读时需结合其他征象。

核心结论

  • 定量超声造影有潜力成为评估儿童克罗恩病活动度的补充方法。
  • 纤维化可能影响峰值增强结果并低估炎症活动。

研究设计与样本

  • 以组织病理学为参考标准,纳入24例经组织病理学确诊的克罗恩病儿童,评估40个肠段。
  • 采用超声评分、主观及定量超声造影评估疾病活动度。
  • 定量超声造影包括增强模式分析、对数时间-强度曲线图形表示及动力学参数计算,并通过受试者工作特征曲线分析确定疾病活动度阈值。
  • 计算常规超声联合彩色多普勒、主观及定量超声造影的诊断准确率。

诊断标准与关键数值

  • 组织病理学显示18个肠段为中重度炎症,22个肠段为缓解或轻度炎症。
  • 定量超声造影峰值增强值预测组织病理学中重度炎症的敏感度为72.2%(95%CI 46.5-90.3)、特异度为100%(95%CI 84.6-100.0)、诊断准确率为87.5%(95%CI 73.2-95.8)。
  • 主观超声造影的敏感度为77.8%(95%CI 52.4-93.6)、特异度为77.3%(95%CI 54.6-92.2)、诊断准确率为77.5%(95%CI 61.6-89.2)。
  • 常规超声联合彩色多普勒的敏感度为55.6%(95%CI 30.8-78.5)、特异度为86.4%(95%CI 65.1-79.1)、诊断准确率为72.5%(95%CI 56.1-85.4)。

临床应用与阅片要点

  • 定量超声造影峰值增强值可作为评估儿童克罗恩病中重度炎症的补充指标,其特异度达100%。
  • 判读峰值增强结果时需考虑纤维化可能低估炎症活动。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

BACKGROUND: Contrast-enhanced ultrasound (US) of the bowel wall has been suggested as an alternative imaging modality for the follow-up of children with Crohn disease.

OBJECTIVE: To evaluate the diagnostic performance of contrast-enhanced US in the estimation of Crohn disease activity in children with histopathology as the reference standard.

MATERIALS AND METHODS: In 24 children with Crohn disease confirmed on histopathology, disease activity was evaluated on 40 bowel segments using US score and subjective and quantitative contrast-enhanced US evaluation. Contrast-enhanced US evaluation included enhancement pattern analysis with a graphic representation of log time-intensity curve and calculation of kinetic parameters with the definition of thresholds for disease activity, as determined by receiver operating characteristics curve analysis. The diagnostic accuracy of US with colour Doppler imaging and subjective and quantitative contrast-enhanced US were calculated.

RESULTS: Moderate or severe inflammation was identified in 18 segments and remission or mild inflammation was identified in 22 segments on histopathology. The quantitative contrast-enhanced US, namely the peak enhancement value, had 72.2% sensitivity (95% confidence interval [CI] 46.5-90.3), 100% specificity (95% CI 84.6-100.0) and 87.5% diagnostic accuracy (95% CI 73.2-95.8) in predicting moderate or severe grade inflammation at histopathology. The sensitivity, specificity and diagnostic accuracy of subjective contrast-enhanced US were 77.8% (95% CI 52.4-93.6), 77.3% (95% CI 54.6-92.2) and 77.5% (95% CI 61.6-89.2), respectively, and of US with colour Doppler imaging were 55.6% (95% CI 30.8-78.5), 86.4% (95% CI 65.1-79.1) and 72.5% (95% CI 56.1-85.4), respectively.

CONCLUSION: Quantitative contrast-enhanced US has the potential of becoming a complementary method in the evaluation of Crohn disease activity in children. Fibrosis may affect peak enhancement results and underestimate inflammatory activity.