MRI鉴别椎体转移瘤与局灶性造血骨髓沉积:质子密度脂肪分数的附加价值
研究纳入44例患者(30个椎体转移瘤和14个局灶性造血骨髓沉积),比较常规MRI与常规MRI联合质子密度脂肪分数(PDFF)对椎体病灶恶性置信度的诊断效能。两位放射科医生阅片显示,联合PDFF后AUC提高(阅片者1从0.840升至0.912,阅片者2从0.805升至0.895),但敏感度和特异度无显著改善(p > .05);观察者间一致性从中等(κ = 0.563)提升至优秀(κ = 0.947)。
要点
- PDFF联合常规MRI可提高鉴别椎体转移瘤与局灶性造血骨髓沉积的诊断效能(AUC提升)。
- PDFF未显著改善敏感度和特异度(p > .05)。
- PDFF使观察者间一致性从中等(κ = 0.563)提升至优秀(κ = 0.947)。
核心结论
- 在常规MRI方案中加入PDFF可提高鉴别椎体转移瘤与局灶性造血骨髓沉积的诊断效能。
- 但加入PDFF未导致敏感度和特异度的显著改善。
研究设计与样本
- 研究纳入44例患者,包含30个椎体转移瘤和14个局灶性造血骨髓沉积,均行脊柱MRI。
- 最终诊断基于组织学确认、随访MRI或PET/CT。
- 两位分别具有1年和15年经验的肌骨放射科医生独立判读常规MRI单独与常规MRI联合PDFF两组图像。
- 采用5分制对椎体病灶恶性置信度进行评分,通过ROC曲线分析评估两组图像的诊断效能(AUC)。
诊断标准与关键数值
- 诊断效能AUC:阅片者1从0.840升至0.912,阅片者2从0.805升至0.895(加入PDFF后)。
- 敏感度和特异度:加入PDFF后两位阅片者均无显著改善(p > .05)。
- 观察者间一致性:从中等(κ = 0.563)提升至优秀(κ = 0.947)(加入PDFF后)。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE. The purpose of this study was to evaluate the added value of proton density fat fraction (PDFF) in differentiating vertebral metastases from focal hematopoietic marrow depositions. MATERIALS AND METHODS. The study included 44 patients with 30 vertebral metastases and 14 focal hematopoietic marrow depositions who underwent spinal MRI. The final diagnoses were based on histologic confirmation, follow-up MRI, or PET/CT. Two musculoskeletal radiologists with 1 and 15 years of experience independently interpreted both image sets (i.e., images from conventional MRI alone versus images from conventional MRI and PDFF combined). Using a 5-point scale, the readers scored their confidence in the malignancy of the vertebral lesions. The diagnostic performance (AUC) of the two image sets was assessed via ROC curve analyses. Sensitivities, specificities, and accuracies (for both image sets) were compared using the McNemar test. Kappa coefficients were calculated to assess interobserver agreement. RESULTS. Both readers showed improved diagnostic performance after PDFF was added (AUC, 0.840-0.912 and 0.805-0.895 for readers 1 and 2, respectively). However, adding PDFF did not significantly improve the sensitivity and specificity of either reader (p > .05). Interobserver agreement significantly improved from moderate (κ = 0.563) to excellent (κ = 0.947) after PDFF was added. CONCLUSION. The addition of PDFF to a conventional MRI protocol improved the diagnostic performance for differentiating vertebral metastases from focal hematopoietic marrow depositions but without resulting in significant improvement in sensitivity and specificity.
引用
- Jung Y, Jeon SW, Kwack KS, et al. Differentiation of Vertebral Metastases From Focal Hematopoietic Marrow Depositions on MRI: Added Value of Proton Density Fat Fraction. AJR Am J Roentgenol. 2021. PMID: 33405947. doi:10.2214/AJR.19.22698
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。