基于超声图像影像组学特征自动准确诊断腕管综合征:与放射科医师评估的比较
研究纳入228例腕(65例患者和57例对照,病例与对照腕数相等),以神经传导检查为金标准,从正中神经B模式超声图像提取影像组学特征并用支持向量机分类,比较两名放射科医师与计算机辅助诊断系统的ROC性能;计算机辅助诊断系统AUC为0.926,高于两名放射科医师基于两种指南的AUC(0.658、0.667和0.736、0.721)。
要点
- 基于正中神经超声影像组学特征的支持向量机分类器诊断腕管综合征的AUC达0.926,高于两名放射科医师的AUC(0.658~0.736)。
- 两名放射科医师间一致性在两种评估指南下均极好。
- 基于指南1,蜂窝状模式在对照腕中清晰出现;基于指南2,腕管综合征腕正中神经束数目显著减少。
关键影像表现/征象
- 基于指南1,蜂窝状模式在对照腕中清晰出现。
- 基于指南2,腕管综合征腕正中神经束数目显著减少。
诊断标准与关键数值
- 放射科医师1的AUC:基于指南1为0.658,基于指南2为0.736。
- 放射科医师2的AUC:基于指南1为0.667,基于指南2为0.721。
- 计算机辅助诊断系统的AUC为0.926,高于两名放射科医师。
- 两名放射科医师间一致性在指南1和指南2下均极好。
临床应用与阅片要点
- 计算机辅助诊断系统基于正中神经超声影像组学特征,可协助放射科医师准确诊断腕管综合征。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: Ultrasonography is the most common imaging modality used to diagnose carpal tunnel syndrome (CTS). Recently artificial intelligence algorithms have been used to diagnose musculoskeletal diseases accurately without human errors using medical images. In this work, a computer-aided diagnosis (CAD) system is developed using radiomics features extracted from median nerves (MN) to diagnose CTS accurately.
METHOD: This study is performed on 228 wrists from 65 patients and 57 controls, with an equal number of control and CTS wrists. Nerve conduction study (NCS) is considered as the gold standard in this study. Two radiologists used two guides to evaluate and categorize the pattern and echogenicity of MNs. Radiomics features are extracted from B-mode ultrasound images (Ultrasomics), and the robust features are fed into support vector machine classifier for automated classification. The diagnostic performances of two radiologists and the CAD system are evaluated using ROC analysis.
RESULTS: The agreement of two radiologists was excellent for both guide 1 and 2. The honey-comb pattern clearly appeared in control wrists (based on guide 1). In addition, CTS wrists indicated significantly lower number of fascicles in MNs (based on guide 2). The area under ROC curve (AUC) of the radiologist 1 and 2 are 0.658 and 0.667 based on guide 1 and 0.736 and 0.721 based on guide 2, respectively. The CAD system indicated higher performance than two radiologists with AUC of 0.926.
CONCLUSION: The proposed CAD system shows the benefit of using ultrasomics features and can assist radiologists to diagnose CTS accurately.
引用
- Faeghi F, Ardakani AA, Acharya UR, et al. Accurate automated diagnosis of carpal tunnel syndrome using radiomics features with ultrasound images: A comparison with radiologists' assessment. Eur J Radiol. 2021. PMID: 33434859. doi:10.1016/j.ejrad.2020.109518