肩胛下肌腱撕裂:磁共振关节造影的诊断效能与可靠性及与关节镜对照和临床试比较
回顾性评估272例经关节镜确诊患者的548例肩关节磁共振关节造影,由两位不同经验肌骨放射科医生将肩胛下肌腱分为完整、部分撕裂和全层撕裂。全层撕裂敏感度71.0%/87.1%、特异度97.3%/98.3%,部分撕裂敏感度72.8%/73.4%、特异度78.3%/81.2%,观察者内和观察者间可靠性好至很好。临床试特异度很高但敏感度和总体准确率均低。
要点
- 全层撕裂特异度达97.3%/98.3%,敏感度71.0%/87.1%,准确率94.4%/95.5%。
- 部分撕裂诊断效能较低,敏感度72.8%/73.4%,准确率76.5%/78.5%。
- 观察者内k=0.85/0.93、观察者间k=0.74-0.89,可靠性好至很好,与经验水平无关。
关键影像表现/征象
- 肩胛下肌腱按MRA表现分为完整肌腱149例、部分厚度撕裂92例和全层撕裂31例。
- 全层撕裂的敏感度、特异度和准确率分别为阅片者1 71.0%、97.3%、94.4%和阅片者2 87.1%、98.3%、95.5%。
- 部分厚度撕裂的敏感度、特异度和准确率分别为阅片者1 72.8%、78.3%、76.5%和阅片者2 73.4%、81.2%、78.5%。
诊断标准与关键数值
- 以关节镜为金标准,全层撕裂阅片者1敏感度71.0%、特异度97.3%、准确率94.4%,阅片者2敏感度87.1%、特异度98.3%、准确率95.5%。
- 部分厚度撕裂阅片者1敏感度72.8%、特异度78.3%、准确率76.5%,阅片者2敏感度73.4%、特异度81.2%、准确率78.5%。
- 观察者内可靠性k=0.85/0.93(p < 0.001),观察者间可靠性k=0.74-0.89(p < 0.001)。
临床应用与阅片要点
- MRA诊断肩胛下肌腱全层撕裂特异度和准确率高,可用于确认全层撕裂。
- 部分厚度撕裂的诊断敏感度和准确率相对较低,阅片时需注意。
- 两位不同经验水平的阅片者间可靠性好至很好,提示MRA判读在不同经验医生间可重复。
- 临床试特异度很高但敏感度和总体准确率低,作者结论未据此给出具体临床推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE: To evaluate the diagnostic performance and reliability of magnetic resonance of arthrography (MRA) in diagnosis of subscapularis (SSC) tendon tears between two reviewers with varying levels of experience, and compare the results with clinical tests.
MATERIALS AND METHODS: SSC tendons were retrospectively evaluated in a total of 272 patients with arthroscopic confirmations. A total of 548 shoulder MRAs were evaluated by two musculoskeletal radiologists, and SSC tendon pathologies were classified into three groups: intact tendon (n = 149), partial-thickness tear (n = 92), or full-thickness tear (n = 31). Diagnostic performance was determined using arthroscopy as gold standard and compared with results of four clinical tests. Intra- and inter-observer reliabilities of two reviewers were evaluated using kappa statistics.
RESULTS: For full-thickness tears, mean values of sensitivity, specificity, and accuracy of reviewer 1/reviewer 2 were 71.0%/87.1%, 97.3%/98.3%, and 94.4%/95.5%, respectively. For partial-thickness tears, mean values of sensitivity, specificity, and accuracy were 72.8%/73.4%, 78.3%/81.2%, and 76.5%/78.5%, respectively. Intra- and inter-observer reliabilities for both reviewers were good to very good (k = 0.85/0.93, p < 0.001; k = 0.74-0.89, p < 0.001). For all clinical tests, while specificity was very high, sensitivity was very low and the overall accuracy was also low.
CONCLUSION: MRA showed high diagnostic performance for the diagnosis of SSC tendon tears, especially full-thickness tears, with good inter- and intra-observer reliabilities, regardless of the level of experience of the reviewer.
引用
- Khil EK, Choi JA, Lee E, et al. Subscapularis (SSC) tendon tears: diagnostic performance and reliability of magnetic resonance arthrography (MRA) with arthroscopic correlation and comparison with clinical tests. Skeletal Radiol. 2021. PMID: 33483772. doi:10.1007/s00256-020-03697-1
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。