四肢多排CT辐射剂量降低:与标准剂量方案图像质量的比较
本研究纳入400例行四肢CT检查者,肩、腕、骨盆、踝关节各50例,分别采用低剂量与标准剂量方案,低剂量CT仅将管电流降至标准剂量的一半。肩和骨盆低剂量CT客观噪声增高且主观图像质量下降,腕关节低剂量CT客观噪声和主观图像质量均未降低,踝关节部分客观与主观测量结果相似。
要点
- 肩和骨盆低剂量CT(管电流减半)客观噪声显著增高、主观图像质量下降,但诊断可接受性仍可接受。
- 腕关节低剂量CT与标准剂量CT的客观噪声无显著差异,主观图像质量除伪影外均相似。
- 踝关节低剂量CT仅部分客观与主观图像质量指标与标准剂量CT相似,其余指标变差。
诊断标准与关键数值
- 客观图像质量以髓质、皮质、肌肉、皮下脂肪和空气CT值的标准差(SD)评价。
- 肩和骨盆低剂量CT所有组织SD均值显著高于标准剂量CT,但肩关节皮质和骨盆骨髓的SD除外。
- 腕关节低剂量与标准剂量CT所有组织SD均值无显著差异(p > 0.05)。
- 踝关节低剂量CT髓质和皮质SD均值无差异(p > 0.05),其余测量低剂量CT显著更高。
临床应用与阅片要点
- 肩和骨盆低剂量CT主观图像质量(噪声、锐利度、诊断可接受性、伪影)显著降低,但诊断性能可接受。
- 腕关节低剂量CT除伪影外所有主观图像质量类别与标准剂量CT相似。
- 踝关节低剂量CT除伪影外所有主观图像质量类别均较标准剂量CT下降。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: To analyze the quantitative and qualitative image quality of computed tomography (CT) of the extremities (shoulder, wrist, pelvis, and ankle joints) with low-dose radiation and standard-dose radiation.
MATERIALS AND METHODS: In this study, we included 400 individuals who underwent CT of the extremities, comprising 50 cases of each joint (shoulder, wrist, pelvis, and ankle) at low and standard dose regimens. Low-dose CTs were performed using identical voltage and parameters with the exception of decreased (half of standard dose) tube current. Low-dose and standard-dose images were compared in terms of radiation dose, objective image quality according to the standard deviation (SD) of the Hounsfield unit value of the medulla, cortex, muscle, subcutaneous fat, and air, and subjective image quality according to noise, sharpness, diagnostic acceptability, and artifacts.
RESULTS: In the shoulder and pelvis, the mean value of the SD for all tissue on low dose CT images was significantly higher than that of standard dose CT, except for the SD of cortex in the shoulder joint and marrow in the pelvis. In the wrist, the mean value of the SD for all tissue was not significantly different between low dose and standard CT (p > 0.05). In the ankle, the mean value of the SD of the medulla and cortex was not different (p > 0.05), but the remaining measurements were significantly higher in low dose CT. Subjective image quality in the shoulder and pelvis were significantly reduced in low dose CT. In the wrist, all categories of subjective image quality except artifacts were similar. In the ankle, all categories of subjective image quality except for artifacts were degraded in low dose CT.
CONCLUSIONS: Objective image noise is more increased in low dose CT images of the shoulder and pelvis. Although diagnostic performance was acceptable, mean subjective image quality also decreased. In the wrist, objective image noise and subjective image quality were not degraded in low dose CT. In the ankle, some measurements of objective and subjective image quality were similar between low dose and standard dose CT.